RVD#2558: Default credentials on SICK PLC allows disabling safety features
The password for the safety PLC is the default and thus easy to find (in manuals, etc.).
No Easyrobotics vulnerabilities are listed in CISA KEV.
5 records in Er-one Firmware · all components
The password for the safety PLC is the default and thus easy to find (in manuals, etc.).
The access tokens for the REST API are directly derived from the publicly available default credentials for the web interface.
The Apache server on port 80 that host the web interface is vulnerable to a DoS by spamming incomplete HTTP headers, effectively blocking the access to the dashboard.
The access tokens for the REST API are directly derived (sha256 and base64 encoding) from the publicly available default credentials from the Control Dashboard (refer to CVE-2020-10270 for related flaws).
There is no mechanism in place to prevent a bad operator to boot from a live OS image, this can lead to extraction of sensible files (such as the shadow file) or privilege escalation by manually adding a new user with su…