Endress+Hauser: Multiple products are vulnerable to code injection
An unauthenticated remote attacker can run malicious c# code included in curve files and execute commands in the users context.
No Endress vulnerabilities are listed in CISA KEV.
23 records
An unauthenticated remote attacker can run malicious c# code included in curve files and execute commands in the users context.
The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
The MEAC300-FNADE4 does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
The maxView Storage Manager does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
Endress+Hauser WirelessHART Fieldgate SWG70 3.x devices allow Directory Traversal via the fcgi-bin/wgsetcgi filename parameter.
The application is vulnerable to SQL injection attacks.
Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) with Firmware version prior to V2.0.0 is prone to improper privilege management.
The configuration of the Apache httpd webserver which serves the MEAC300-FNADE4 web application, is partly insecure.
During startup, the device automatically logs in the EPC2 Windows user without requesting a password.
The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker.
All communication between the VNC server and client(s) is unencrypted.
Multiple services of the DUT as well as different scopes of the same service reuse the same credentials.
The VNC application stores its passwords encrypted within the registry but uses DES for encryption.
The VNC authentication mechanism bases on a challenge-response system where both server and client use the same password for encryption.
The web application is susceptible to cross-site-scripting attacks.
For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a non-existing username.
The web application is susceptible to cross-site-scripting attacks.
Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) and Memograph M (Neutral/Private Label) (RSG45, ORSG45) with Firmware version V2.0.0 and above is prone to exposure of sensitive information to an unautho…
The HttpOnly flag is set to false on the PHPSESSION cookie.
The Secure attribute is missing on multiple cookies provided by the MEAC300-FNADE4.
Several credentials for the local PostgreSQL database are stored in plain text (partially base64 encoded).
The web application is vulnerable to clickjacking attacks.
The application is vulnerable to cross-site request forgery.