Records121All Threatist records
Exploited (KEV)2In CISA KEV
CVSS critical12CVSS 9.0–10.0
CVSS high57CVSS 7.0–8.9
Exploited now
Philips records in CISA KEVComponents
Products in the NVD configurations · select one to filter the recordsPriority MEDIUM 49
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.03834 · Published 2018-09-26 · No fix listed CWE-20
Priority MEDIUM 45
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01378 · Published 2018-09-26 · No fix listed CWE-798
Priority MEDIUM 42
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0HIGH 8.8· Network · No auth · User interaction · EPSS 0.01897 · Published 2018-09-26 · No fix listed CWE-384
Priority MEDIUM 40
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0HIGH 8.8· Network · No auth · User interaction · EPSS 0.00873 · Published 2018-09-26 · No fix listed CWE-352
Priority LOW 39
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0HIGH 8.8· Adjacent network · No auth · No interaction · EPSS 0.0057 · Published 2018-09-26 · No fix listed CWE-319
Priority LOW 38
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.02523 · Published 2018-09-26 · No fix listed CWE-400
Priority LOW 37
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.02026 · Published 2018-09-26 · No fix listed CWE-276
Priority LOW 30
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0MEDIUM 6.1· Network · No auth · User interaction · EPSS 0.01259 · Published 2018-09-26 · No fix listed CWE-79
Priority LOW 29
The software does not perform any authentication for critical system functionality.
CVSS 3.1MEDIUM 6.5· Adjacent network · No auth · No interaction · EPSS 0.00396 · Published 2022-04-01 · Fixed in 2.7 CWE-306
Priority LOW 28
Philips e-Alert Unit (non-medical device), Version R2.1 and prior.
CVSS 3.0MEDIUM 5.3· Network · No auth · No interaction · EPSS 0.01738 · Published 2018-09-26 · No fix listed CWE-200
Open these records in search →