Softing Secure Integration Server Improper Authentication
Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`.
No Softing vulnerabilities are listed in CISA KEV.
17 records in Opc · all components
Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`.
The application searches for a library dll that is not found.
The “restore configuration” feature of Softing Secure Integration Server V1.22 is vulnerable to a directory traversal vulnerability when processing zip files.
Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Secure Integration Server V1.22.
A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability.
An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating system may cause the application to crash when the server wants to send an error packet, while socket is blocked on writi…
Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain sensitive information via weak permissions in OSF_discovery service.
An issue was discovered in Softing OPC UA C++ SDK 5.66 through 6.x before 6.10.
An issue was discovered in Softing OPC UA C++ SDK before 6.10.
Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to uncontrolled resource consumption, which may allow an attacker to cause a denial-of-service co…
An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40.
An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66.
Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack.