Priority CRITICAL 89
In multiple products of WAGO a vulnerability allows an unauthenticated, remote attacker to create new users and change the device configuration which can result in unintended behaviour, Denial of Service and full system…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.81911 · Published 2023-05-15 · No fix listed CWE-78
Priority MEDIUM 48
An exploitable heap buffer overflow vulnerability exists in the iocheckd service I/O-Check functionality of WAGO PFC200 Firmware version 03.01.07(13), WAGO PFC200 Firmware version 03.00.39(12), and WAGO PFC100 Firmware v…
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.03316 · Published 2020-01-08 · No fix listed CWE-787
Priority MEDIUM 45
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01067 · Published 2023-02-27 · Fixed in FW22, FW22 Patch 1 CWE-306
Priority MEDIUM 45
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions.
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.03461 · Published 2019-04-17 · Fixed in v1.10.0.0, v1.0 +1 CWE-400
Priority MEDIUM 43
The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API.
CVSS 3.1CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.0074 · Published 2023-02-27 · Fixed in FW22, FW22 Patch 1 CWE-306
Priority LOW 37
An exploitable regular expression without anchors vulnerability exists in the Web-Based Management (WBM) authentication functionality of WAGO PFC200 versions 03.00.39(12) and 03.01.07(13), and WAGO PFC100 version 03.00.3…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.02254 · Published 2020-03-10 · No fix listed
Priority LOW 36
The WBM web application on firmwares prior to 03.02.02 and 03.01.07 on the WAGO PFC100 and PFC2000, respectively, runs on a lighttpd web server and makes use of the FastCGI module, which is intended to provide high perfo…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.01804 · Published 2020-03-10 · No fix listed CWE-400
Priority LOW 27
The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser.
CVSS 3.1MEDIUM 6.1· Network · No auth · User interaction · EPSS 0.00375 · Published 2023-02-27 · Fixed in FW22, FW22 Patch 1 CWE-79
Priority LOW 27
The vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists.
CVSS 3.1MEDIUM 5.9· Network · No auth · No interaction · EPSS 0.00642 · Published 2023-01-19 · No fix listed CWE-306
Priority LOW 26
An exploitable timing discrepancy vulnerability exists in the authentication functionality of the Web-Based Management (WBM) web application on WAGO PFC100/200 controllers.
CVSS 3.1MEDIUM 5.3· Network · No auth · No interaction · EPSS 0.01047 · Published 2020-03-10 · No fix listed CWE-327
Priority LOW 24
A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver.
CVSS 3.1MEDIUM 5.3· Network · No auth · No interaction · EPSS 0.00254 · Published 2023-02-27 · Fixed in FW22, FW22 Patch 1 CWE-346
Priority LOW 23
Wago web-based management of multiple products has a vulnerability which allows an local authenticated attacker to change the passwords of other non-admin users and thus to escalate non-root privileges.
CVSS 3.1MEDIUM 5.3· Local · Low privileges · No interaction · EPSS 0.00197 · Published 2023-11-20 · No fix listed CWE-863
Priority LOW 15
On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion.
CVSS 3.1LOW 2.7· Network · High privileges · No interaction · EPSS 0.0063 · Published 2023-10-17 · No fix listed CWE-610