Command injection in power analyzer via Modbus-TCP and Modbus-RTU
An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.
No Weidmueller vulnerabilities are listed in CISA KEV.
35 records
An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.
An unauthenticated remote attacker may use a stack based buffer overflow in the u-link Management API to gain full access on the affected devices.
For u-link Management API an unauthenticated remote attacker in a man-in-the-middle position can inject arbitrary commands in responses returned by WWH servers, which are then executed with elevated privileges.
Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leadi…
An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product.
The devices are vulnerable to an authentication bypass due to flaws in the authorization mechanism.
An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices.
An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices.
An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices.
In Weidmüller u-controls and IoT-Gateways in versions up to 1.12.1 a network port intended only for device-internal usage is accidentally accessible via external network interfaces.
An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint tls_iotgen_setting).
An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint event_mail_test).
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in the iw_webs functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable command injection vulnerability exists in encrypted diagnostic script functionality of the devices.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable format string vulnerability exists in the iw_console conio_writestr functionality.
An unauthenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of Cross-Site Request Forgery (CSRF) protection.
An unauthenticated remote attacker can exploit a denial-of-service vulnerability in the device's web server functionality by sending a specially crafted HTTP request with a malicious header, potentially causing the serve…
In Weidmueller Industrial WLAN devices in multiple versions an exploitable improper access control vulnerability exists in the iw_webs account settings functionality.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable privilege escalation vulnerability exists in the iw_console functionality.
An unauthenticated remote attacker can exploit input validation in cmd services of the devices, allowing them to disrupt system operations and potentially cause a denial-of-service.
An unauthenticated remote attacker can exploit insufficient input validation to write data beyond the bounds of a buffer, potentially leading to a denial-of-service condition for the devices.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable use of hard-coded credentials vulnerability exists in multiple iw_* utilities.
M&M Software fdtCONTAINER Component in versions below 3.5.20304.x and between 3.6 and 3.6.20304.x is vulnerable to deserialization of untrusted data in its project storage.