Read the docs
TI-2011-03561 Aliases CVE-2011-4034GHSA-fqp8-j3rg-x5gf

Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric…

Priority MEDIUM 55CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
— Not recorded in CVSS 2.0
Attack complexity
Medium
Impact type
Code execution
Confidentiality · integrity · availability
Complete · Complete · Complete
Fix status
No fix listed

Attack profile from CVSS 2.0 · NVD. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.

Why it matters now

EPSS 0.13368 96th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 8

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*up to 4.30VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*4.0VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*4.10VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*4.20VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*up to 4.30VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*4.20VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*up to 4.10VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*4.0VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:* Versions up to 4.30 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:* Versions 4.0 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:* Versions 4.10 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:* Versions 4.20 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:* Versions up to 4.30 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:* Versions 4.20 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:* Versions up to 4.10 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:* Versions 4.0 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2011-4034
  2. 2026-10-03 Alias added: GHSA-fqp8-j3rg-x5gf

References

  • TI-2011-03563 Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier… CVSS 2.0MEDIUM 5.0
  • TI-2011-03562 Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and… CVSS 2.0MEDIUM 4.3
  • TI-2011-03560 Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric… CVSS 2.0MEDIUM 4.3

Sources