Read the docs
TI-2012-01588 Aliases CVE-2012-1803GHSA-qgxr-qjc2-5hqj

RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a…

Priority HIGH 68CWE-310Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
— Not recorded in CVSS 2.0
Attack complexity
Medium
Impact type
—
Confidentiality · integrity · availability
Complete · Complete · Complete
Fix status
No fix listed

Attack profile from CVSS 2.0 · NVD. Fix status from CNA.

Summary

RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.

Why it matters now

EPSS 0.48882 98th percentileScored 2026-11-07
Public exploit Yes 2 exploit referencesTagged by the CNA and NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:o:siemens:ruggedcom_rugged_operating_system:*:*:*:*:*:*:*:*3.2.0 – 3.10.1VulnerableSiemens
  • cpe:2.3:o:siemens:ruggedcom_rugged_operating_system:*:*:*:*:*:*:*:* Versions 3.2.0 – 3.10.1 Vulnerable ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2012-1803
  2. 2026-10-03 Alias added: GHSA-qgxr-qjc2-5hqj

References

  • TI-2012-02162 RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password… CVSS 2.0HIGH 8.5
  • TI-2013-05689 The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote… CVSS 2.0HIGH 8.3
  • TI-2014-01535 The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS… CVSS 2.0HIGH 7.8
  • TI-2013-05690 The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote… CVSS 2.0HIGH 8.0
  • TI-2014-02075 The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5… CVSS 2.0MEDIUM 5.0
  • TI-2015-05593 Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature… CVSS 2.0MEDIUM 4.3
See all 8 →

Sources