SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used…
Priority LOW 37CWE-89Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- — Not recorded in CVSS 2.0
- Attack complexity
- Low
- Impact type
- SQL injection
- Confidentiality · integrity · availability
- Partial · Partial · Partial
- Fix status
- No fix listed
Attack profile from CVSS 2.0 · NVD. Fix status from CNA. Impact type from CWE-89.
Summary
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
Why it matters now
EPSS 0.02405 84th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 11
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:* | 8.0 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:* | up to 7.0 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:* | 5.0 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:* | 5.0 sp1 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:* | 6.0 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:* | 6.0 sp2 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:* | 6.0 sp3 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:* | 6.0 sp4 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:* | 7.0 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:* | 7.0 sp1 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:* Versions 8.0 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:* Versions up to 7.0 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:* Versions 5.0 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:* Versions 5.0 sp1 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:* Versions 6.0 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:* Versions 6.0 sp2 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:* Versions 6.0 sp3 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:* Versions 6.0 sp4 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:* Versions 7.0 Vulnerable ·Siemens
- cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:* Versions 7.0 sp1 Vulnerable ·Siemens
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2012-3032
- 2026-10-03 Alias added: GHSA-3xrj-qr54-846w
References
More Siemens Simatic Pcs7 vulnerabilities
- TI-2014-07026 The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3… CVSS 2.0HIGH 10.0
- TI-2017-08864 An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before… CVSS 3.0HIGH 8.2
- TI-2013-03460 The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as… CVSS 2.0HIGH 7.5
- TI-2013-03459 SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC… CVSS 2.0HIGH 7.5
- TI-2013-00565 Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in… CVSS 2.0MEDIUM 6.8
- TI-2014-03858 The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in… CVSS 2.0MEDIUM 6.8
Sources
- CVE-2012-3032 · CVE Program
- CVE-2012-3032 · NVD
- FIRST EPSS
- GHSA-3xrj-qr54-846w · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences