Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager…
Priority MEDIUM 62CWE-119Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- — Not recorded in CVSS 2.0
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- Complete · Complete · Complete
- Fix status
- No fix listed
Attack profile from CVSS 2.0 · NVD. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.
Summary
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
Why it matters now
EPSS 0.21527 97th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:schneider-electric:accutech_manager:*:*:*:*:*:*:*:* | up to 2.00.1 | Vulnerable | Schneider Electric |
- cpe:2.3:a:schneider-electric:accutech_manager:*:*:*:*:*:*:*:* Versions up to 2.00.1 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2013-0658
- 2026-10-03 Alias added: GHSA-44jc-mmwc-23qh
References
More Schneider Electric Accutech Manager vulnerabilities
- TI-2023-13794 Buffer overflow in Schneider Electric Accutech Manager CVSS 3.1HIGH 7.8
Sources
- CVE-2013-0658 · CVE Program
- CVE-2013-0658 · NVD
- FIRST EPSS
- GHSA-44jc-mmwc-23qh · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences