Read the docs
TI-2013-04298 Aliases CVE-2013-4911GHSA-prww-5xcf-552x

Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12…

Priority LOW 32CWE-352Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
— Not recorded in CVSS 2.0
Attack complexity
Medium
Impact type
Tampering
Confidentiality · integrity · availability
Partial · Partial · Partial
Fix status
No fix listed

Attack profile from CVSS 2.0 · NVD. Fix status from CNA. Impact type from CWE-352.

Summary

Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.

Why it matters now

EPSS 0.0108 65th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:a:siemens:wincc:11.0:*:*:*:*:*:*:*11.0VulnerableSiemens
cpe:2.3:a:siemens:wincc:11.0:sp1:*:*:*:*:*:*11.0 sp1VulnerableSiemens
cpe:2.3:a:siemens:wincc:11.0:sp2:*:*:*:*:*:*11.0 sp2VulnerableSiemens
cpe:2.3:a:siemens:wincc:12.0:*:*:*:*:*:*:*12.0VulnerableSiemens
  • cpe:2.3:a:siemens:wincc:11.0:*:*:*:*:*:*:* Versions 11.0 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:wincc:11.0:sp1:*:*:*:*:*:* Versions 11.0 sp1 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:wincc:11.0:sp2:*:*:*:*:*:* Versions 11.0 sp2 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:wincc:12.0:*:*:*:*:*:*:* Versions 12.0 Vulnerable ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2013-4911
  2. 2026-10-03 Alias added: GHSA-prww-5xcf-552x

References

  • TI-2011-04195 Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible… CVSS 2.0HIGH 9.3
  • TI-2011-04196 Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC… CVSS 2.0HIGH 9.3
  • TI-2011-04199 miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008… CVSS 2.0HIGH 8.5
  • TI-2011-03885 Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP… CVSS 2.0HIGH 10.0
  • TI-2011-03886 The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka… CVSS 2.0HIGH 10.0
  • TI-2011-04198 Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC… CVSS 2.0HIGH 7.8
See all 42 →

Sources