Read the docs
TI-2013-04390 Aliases CVE-2013-5021GHSA-j5xx-ggqq-g4cw

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as…

Priority MEDIUM 44CWE-22Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
— Not recorded in CVSS 2.0
Attack complexity
Medium
Impact type
—
Confidentiality · integrity · availability
Complete · Complete · Complete
Fix status
No fix listed

Attack profile from CVSS 2.0 · NVD. Fix status from CNA.

Summary

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

Why it matters now

EPSS 0.02073 81st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*up to 2012VulnerableNI
cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*up to 2012VulnerableNI
cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*up to 2013VulnerableNI
cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*up to 2012VulnerableNI
cpe:2.3:a:abb:datamanager:1.0.0:*:*:*:*:*:*:*1.0.0VulnerableABB
cpe:2.3:a:abb:datamanager:6.3.6:*:*:*:*:*:*:*6.3.6VulnerableABB
  • cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:* Versions up to 2012 Vulnerable ·NI
  • cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:* Versions up to 2012 Vulnerable ·NI
  • cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:* Versions up to 2013 Vulnerable ·NI
  • cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:* Versions up to 2012 Vulnerable ·NI
  • cpe:2.3:a:abb:datamanager:1.0.0:*:*:*:*:*:*:* Versions 1.0.0 Vulnerable ·ABB
  • cpe:2.3:a:abb:datamanager:6.3.6:*:*:*:*:*:*:* Versions 6.3.6 Vulnerable ·ABB

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2013-5021
  2. 2026-10-03 Alias added: GHSA-j5xx-ggqq-g4cw

References

Sources