Read the docs
TI-2014-01310 Aliases CVE-2014-1697GHSA-pjpr-3jp2-8fm3

The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows…

Priority MEDIUM 41Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
— Not recorded in CVSS 2.0
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Partial · Partial · Partial
Fix status
No fix listed

Attack profile from CVSS 2.0 · NVD. Fix status from CNA.

Summary

The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.

Why it matters now

EPSS 0.05261 92nd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*up to 3.12VulnerableSiemens
  • cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:* Versions up to 3.12 Vulnerable ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2014-1697
  2. 2026-10-03 Alias added: GHSA-pjpr-3jp2-8fm3

References

  • TI-2018-02959 An exploitable heap overflow vulnerability exists in the WkbProgramLow function of… CVSS 3.0CRITICAL 10.0
  • TI-2018-10011 Improper privilege management in Siemens SIMATIC WinCC OA V3.14 and prior CVSS 3.0CRITICAL 9.1
  • TI-2020-06103 A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2)… CVSS 3.1MEDIUM 6.7
  • TI-2014-01311 Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January… CVSS 2.0MEDIUM 5.0
  • TI-2019-08150 Broken or risky cryptographic algorithm in Siemens SIMATIC CP 1626 CVSS 3.1MEDIUM 5.9
  • TI-2014-01312 Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a… CVSS 2.0MEDIUM 5.0
See all 7 →