Siemens SPC controllers SPC4000, SPC5000, and SPC6000 before 3.6.0 allow remote attackers…
Priority LOW 38CWE-20Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- — Not recorded in CVSS 2.0
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- None · None · Complete
- Fix status
- No fix listed
Attack profile from CVSS 2.0 · NVD. Fix status from CNA.
Summary
Siemens SPC controllers SPC4000, SPC5000, and SPC6000 before 3.6.0 allow remote attackers to cause a denial of service (device restart) via crafted packets.
Why it matters now
EPSS 0.02292 83rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 6
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:siemens:spc5000_firmware:*:*:*:*:*:*:*:* | up to 3.5.9 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:spc5000:*:*:*:*:*:*:*:* | all versions | Running on | Siemens |
| cpe:2.3:o:siemens:spc4000_firmware:*:*:*:*:*:*:*:* | up to 3.5.9 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:spc4000:*:*:*:*:*:*:*:* | all versions | Running on | Siemens |
| cpe:2.3:o:siemens:spc6000_firmware:*:*:*:*:*:*:*:* | up to 3.5.9 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:spc6000:*:*:*:*:*:*:*:* | all versions | Running on | Siemens |
- cpe:2.3:o:siemens:spc5000_firmware:*:*:*:*:*:*:*:* Versions up to 3.5.9 Vulnerable ·Siemens
- cpe:2.3:h:siemens:spc5000:*:*:*:*:*:*:*:* Versions all versions Running on ·Siemens
- cpe:2.3:o:siemens:spc4000_firmware:*:*:*:*:*:*:*:* Versions up to 3.5.9 Vulnerable ·Siemens
- cpe:2.3:h:siemens:spc4000:*:*:*:*:*:*:*:* Versions all versions Running on ·Siemens
- cpe:2.3:o:siemens:spc6000_firmware:*:*:*:*:*:*:*:* Versions up to 3.5.9 Vulnerable ·Siemens
- cpe:2.3:h:siemens:spc6000:*:*:*:*:*:*:*:* Versions all versions Running on ·Siemens
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2014-9369
- 2026-10-03 Alias added: GHSA-p6h9-x3xm-8v52
References
Sources
- CVE-2014-9369 · CVE Program
- CVE-2014-9369 · NVD
- FIRST EPSS
- GHSA-p6h9-x3xm-8v52 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences