Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC…
Priority LOW 26CWE-200Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Information disclosure
- Confidentiality · integrity · availability
- Low · None · None
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-200.
Summary
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
Why it matters now
EPSS 0.01176 67th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 9
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:schneider-electric:telvent_rtu_firmware:*:*:*:*:*:*:*:* | up to c3414-500-s02j1 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_3030m:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_landac_ii-2:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:h:schneider-electric:sage_2300:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:telvent_rtu_firmware:*:*:*:*:*:*:*:* | up to c3413-500-001d3 | Vulnerable | Schneider Electric |
- cpe:2.3:o:schneider-electric:telvent_rtu_firmware:*:*:*:*:*:*:*:* Versions up to c3414-500-s02j1 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_3030m:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_landac_ii-2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:h:schneider-electric:sage_2300:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:telvent_rtu_firmware:*:*:*:*:*:*:*:* Versions up to c3413-500-001d3 Vulnerable ·Schneider Electric
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2015-6485
- 2026-10-03 Alias added: GHSA-7qxm-j3q6-829g
References
Sources
- CVE-2015-6485 · CVE Program
- CVE-2015-6485 · NVD
- FIRST EPSS
- GHSA-7qxm-j3q6-829g · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences