Origin validation error in Smiths-Medical CADD-Solis Medication Safety Software through…
Priority LOW 37CWE-346Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- High
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-346.
Summary
An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.
Why it matters now
EPSS 0.005 43rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | Smiths-Medical CADD-Solis Medication Safety Software through 3.1 | Smiths-Medical CADD-Solis Medication Safety Software through 3.1 | — | No fix listed | CNA |
- Smiths-Medical CADD-Solis Medication Safety Software through 3.1 Vendor— Affected Smiths-Medical CADD-Solis Medication Safety Software through 3.1 Fixed in — No fix listed CNA
CPE configurations NVD · 4
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:1.0:*:*:*:*:*:*:* | 1.0 | Vulnerable | Smiths-medical |
| cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:2.0:*:*:*:*:*:*:* | 2.0 | Vulnerable | Smiths-medical |
| cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:3.0:*:*:*:*:*:*:* | 3.0 | Vulnerable | Smiths-medical |
| cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:3.1:*:*:*:*:*:*:* | 3.1 | Vulnerable | Smiths-medical |
- cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:1.0:*:*:*:*:*:*:* Versions 1.0 Vulnerable ·Smiths-medical
- cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:2.0:*:*:*:*:*:*:* Versions 2.0 Vulnerable ·Smiths-medical
- cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:3.0:*:*:*:*:*:*:* Versions 3.0 Vulnerable ·Smiths-medical
- cpe:2.3:a:smiths-medical:cadd-solis_medication_safety_software:3.1:*:*:*:*:*:*:* Versions 3.1 Vulnerable ·Smiths-medical
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2016-8358
- 2026-10-03 Alias added: GHSA-6c6r-7283-r9ph
References
More Smiths-medical Cadd-solis Medication Safety Software vulnerabilities
- TI-2016-06864 Missing authentication in Smiths-Medical CADD-Solis Medication Safety Software through 3.1 CVSS 3.0CRITICAL 9.9
Sources
- CVE-2016-8358 · CVE Program
- CVE-2016-8358 · NVD
- FIRST EPSS
- GHSA-6c6r-7283-r9ph · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences