A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl.

Priority LOW 28CWE-200Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
Low · None · None
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-200.

Summary

A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission.

Why it matters now

EPSS 0.01892 79th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 8

CPEVersionsRoleVendor
cpe:2.3:o:siemens:simatic_cp_343-1_firmware:-:*:*:*:advanced:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_s7_300_cpu_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_s7_300_cpu:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_s7_400_cpu_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_s7_400_cpu:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_cp_443-1_firmware:-:*:*:*:advanced:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:simatic_cp_343-1_firmware:-:*:*:*:advanced:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_s7_300_cpu_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_s7_300_cpu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_s7_400_cpu_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_s7_400_cpu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_cp_443-1_firmware:-:*:*:*:advanced:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2016-8672
  2. 2026-10-03 Alias added: GHSA-php6-577h-8wj4

References

  • TI-2015-06768 A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. CVSS 2.0HIGH 9.7
  • TI-2019-10399 Uncontrolled resource consumption in Siemens Development/Evaluation Kits for PROFINET IO… CVSS 3.1HIGH 7.5
  • TI-2016-07131 A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. CVSS 3.0HIGH 8.8
  • TI-2021-13111 Memory corruption in Siemens SIMATIC CP 343-1 CVSS 3.1HIGH 7.5
  • TI-2023-28094 Improper verification of communication channel in Siemens SIMATIC CP 343-1 CVSS 3.1HIGH 7.5
  • TI-2018-03420 Improper input validation in Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 CVSS 3.1MEDIUM 6.5

Sources