TI-2017-04604 Aliases CVE-2017-6867GHSA-f7g5-6g5q-8c2q

Out-of-bounds write in Siemens SIMATIC WinCC

Priority LOW 26CWE-787Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.

Summary

A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface.

Why it matters now

EPSS 0.01923 80th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Siemens SIMATIC WinCCSiemens SIMATIC WinCC—No fix listedCNA
  • Siemens SIMATIC WinCC Vendor— Affected Siemens SIMATIC WinCC Fixed in — No fix listed CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*7.3VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*7.4VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13:sp1:*:*:professional:*:*:*13 sp1VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14:*:*:*:professional:*:*:*14VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*13 sp1VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*14VulnerableSiemens
  • cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:* Versions 7.3 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:* Versions 7.4 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13:sp1:*:*:professional:*:*:* Versions 13 sp1 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14:*:*:*:professional:*:*:* Versions 14 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:* Versions 13 sp1 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:* Versions 14 Vulnerable ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2017-6867
  2. 2026-10-03 Alias added: GHSA-f7g5-6g5q-8c2q

References

  • TI-2016-04985 Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before… CVSS 3.0CRITICAL 9.8
  • TI-2014-07026 The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3… CVSS 2.0HIGH 10.0
  • TI-2019-08143 Missing authentication in Siemens SIMATIC PCS 7 V8.0 and earlier CVSS 3.1CRITICAL 9.8
  • TI-2021-17429 Path traversal in Siemens SIMATIC PCS 7 V8.2 CVSS 3.1CRITICAL 9.9
  • TI-2019-08139 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions)… CVSS 3.1HIGH 8.8
  • TI-2019-08137 SQL injection in Siemens SIMATIC PCS 7 V8.0 and earlier CVSS 3.1HIGH 8.8
See all 29 →