Recently it was discovered as a part of the research on IoT devices in the most recent…
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.
Summary
Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries. The firmware contains binary uvc_stream that is the UDP daemon which is responsible for handling all the UDP requests that the device receives. The client application sends a UDP request to change the Wi-Fi name which contains the following format: "SETCMD0001+0001+[2 byte length of wifiname]+[Wifiname]. This request is handled by "control_Dev_thread" function which at address "0x00409AE0" compares the incoming request and determines if the 10th byte is 01 and if it is then it redirects to 0x0040A74C which calls the function "setwifiname". The function "setwifiname" uses a memcpy function but uses the length of the payload obtained by using strlen function as the third parameter which is the number of bytes to copy and this allows an attacker to overflow the function and control the $PC value.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2017-10723
- 2026-10-03 Alias added: GHSA-8mjp-v767-xr8v
References
More Ishekar Endoscope Camera Firmware vulnerabilities
- TI-2017-07832 Recently it was discovered as a part of the research on IoT devices in the most recent… CVSS 3.0HIGH 8.8
- TI-2017-07830 Recently it was discovered as a part of the research on IoT devices in the most recent… CVSS 3.0HIGH 7.8
- TI-2017-07828 Recently it was discovered as a part of the research on IoT devices in the most recent… CVSS 3.0HIGH 7.8
- TI-2017-07827 Recently it was discovered as a part of the research on IoT devices in the most recent… CVSS 3.0MEDIUM 6.5
- TI-2017-07829 Recently it was discovered as a part of the research on IoT devices in the most recent… CVSS 3.0MEDIUM 6.5
- TI-2017-07826 Recently it was discovered as a part of the research on IoT devices in the most recent… CVSS 3.0MEDIUM 6.5
Sources
- CVE-2017-10723 · CVE Program
- CVE-2017-10723 · NVD
- FIRST EPSS
- GHSA-8mjp-v767-xr8v · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences