Hard-coded credentials in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump

Priority LOW 34CWE-798Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-798.

Summary

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.

Why it matters now

EPSS 0.01082 65th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Smiths Medical Medfusion 4000 Wireless Syringe Infusion PumpSmiths Medical Medfusion 4000 Wireless Syringe Infusion Pump—No fix listedCNA
  • Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vendor— Affected Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.1:*:*:*:*:*:*:*1.1VulnerableSmiths-medical
cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.5:*:*:*:*:*:*:*1.5VulnerableSmiths-medical
cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.6:*:*:*:*:*:*:*1.6VulnerableSmiths-medical
cpe:2.3:h:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:-:*:*:*:*:*:*:*not specified by NVDRunning onSmiths-medical
  • cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.1:*:*:*:*:*:*:* Versions 1.1 Vulnerable ·Smiths-medical
  • cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.5:*:*:*:*:*:*:* Versions 1.5 Vulnerable ·Smiths-medical
  • cpe:2.3:o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.6:*:*:*:*:*:*:* Versions 1.6 Vulnerable ·Smiths-medical
  • cpe:2.3:h:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Smiths-medical

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2017-12726
  2. 2026-10-03 Alias added: GHSA-qx9v-89v8-vq65

References

  • TI-2017-09424 Buffer overflow in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump CVSS 3.0HIGH 8.1
  • TI-2017-09426 Missing authentication in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump CVSS 3.0HIGH 8.1
  • TI-2017-09430 Hard-coded credentials in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump CVSS 3.0HIGH 8.1
  • TI-2017-09428 Out-of-bounds read in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump CVSS 3.0MEDIUM 5.3
  • TI-2017-09427 Improper certificate validation in Smiths Medical Medfusion 4000 Wireless Syringe… CVSS 3.0MEDIUM 5.9
  • TI-2017-09431 Hard-coded credentials in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump CVSS 3.0MEDIUM 5.6
See all 7 →

Sources