An FBX-5313 issue was discovered in WatchGuard Fireware before 12.0.
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-79.
Summary
An FBX-5313 issue was discovered in WatchGuard Fireware before 12.0. When a failed login attempt is made to the login endpoint of the XML-RPC interface, if JavaScript code, properly encoded to be consumed by XML parsers, is embedded as value of the user element, the code will be rendered in the context of any logged in user in the Web UI visiting "Traffic Monitor" sections "Events" and "All." As a side effect, no further events will be visible in the Traffic Monitor until the device is restarted.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:watchguard:fireware:*:*:*:*:*:*:*:* | up to 11.12.4 | Vulnerable | WatchGuard |
- cpe:2.3:o:watchguard:fireware:*:*:*:*:*:*:*:* Versions up to 11.12.4 Vulnerable ·WatchGuard
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2017-14615
- 2026-10-03 Alias added: GHSA-vgjf-cq8h-569f
References
Exploit 2
More WatchGuard Fireware vulnerabilities
- TI-2022-09698 On WatchGuard Firebox and XTM appliances, an unauthenticated user can execute arbitrary… KEVCVSS 3.1CRITICAL 9.8
- TI-2025-13451 WatchGuard Firebox iked Out of Bounds Write Vulnerability KEVCVSS 4.0CRITICAL 9.3
- TI-2025-08474 WatchGuard Firebox iked Out of Bounds Write Vulnerability KEVCVSS 4.0CRITICAL 9.3
- TI-2022-07330 WatchGuard Firebox and XTM appliances allow a remote attacker with unprivileged… KEVCVSS 3.1HIGH 8.8
- TI-2013-05132 Buffer overflow in WGagent in WatchGuard WSM and Fireware before 11.8 allows remote… CVSS 2.0HIGH 9.3
- TI-2026-02885 WatchGuard Firebox Out of Bounds Write Vulnerability CVSS 4.0HIGH 8.6
Sources
- CVE-2017-14615 · CVE Program
- CVE-2017-14615 · NVD
- FIRST EPSS
- GHSA-vgjf-cq8h-569f · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences