SYN Flood or FIN Flood attack in ECos 1 and other versions embedded devices results in…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-287.
Summary
SYN Flood or FIN Flood attack in ECos 1 and other versions embedded devices results in web Authentication Bypass. "eCos Embedded Web Servers used by Multiple Routers and Home devices, while sending SYN Flood or FIN Flood packets fails to validate and handle the packets and does not ask for any sign of authentication resulting in Authentication Bypass. An attacker can take complete advantage of this bug and take over the device remotely or locally. The bug has been successfully tested and reproduced in some versions of SOHO Routers manufactured by TOTOLINK, GREATEK and others."
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| — | — | all versions | — | No fix listed | CNA |
- — Vendor— Affected all versions Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2017-1000020
- 2026-10-03 Alias added: GHSA-76v3-hrq5-hh93
References
Sources
- CVE-2017-1000020 · CVE Program
- CVE-2017-1000020 · NVD
- FIRST EPSS
- GHSA-76v3-hrq5-hh93 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences