TI-2018-03415 Aliases CVE-2018-4838GHSA-r849-hjqv-324f

Missing authentication in Siemens EN100 Ethernet module IEC 61850 variant

Priority LOW 36CWE-306Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
None · High · None
Fix status
Fixed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-306.

Summary

A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.

Why it matters now

EPSS 0.01404 72nd percentileScored 2026-11-07
Fix Fixed EN100 Ethernet module IEC 61850 variant (Siemens AG): V4.30EN100 Ethernet module DNP3 variant (Siemens AG): V1.04+1 more product

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensEN100 Ethernet module IEC 61850 variantbefore V4.30V4.30Patch availableCNA
SiemensEN100 Ethernet module DNP3 variantbefore V1.04V1.04Patch availableCNA
SiemensEN100 Ethernet module PROFINET IO variantAll versions—No fix listedCNA
SiemensEN100 Ethernet module Modbus TCP variantAll versions—No fix listedCNA
SiemensEN100 Ethernet module IEC 104 variantbefore V1.22V1.22Patch availableCNA
  • EN100 Ethernet module IEC 61850 variant VendorSiemens Affected before V4.30 Fixed in V4.30 Patch available CNA
  • EN100 Ethernet module DNP3 variant VendorSiemens Affected before V1.04 Fixed in V1.04 Patch available CNA
  • EN100 Ethernet module PROFINET IO variant VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • EN100 Ethernet module Modbus TCP variant VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • EN100 Ethernet module IEC 104 variant VendorSiemens Affected before V1.22 Fixed in V1.22 Patch available CNA

CPE configurations NVD · 10

CPEVersionsRoleVendor
cpe:2.3:o:siemens:en100_ethernet_module_iec_104_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:en100_ethernet_module_iec_104:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:en100_ethernet_module_dnp3_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:en100_ethernet_module_dnp3:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:en100_ethernet_module_modbus_tcp_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:en100_ethernet_module_modbus_tcp:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:en100_ethernet_module_profinet_io_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:en100_ethernet_module_profinet_io:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:en100_ethernet_module_iec_61850_firmware:*:*:*:*:*:*:*:*before 4.30VulnerableSiemens
cpe:2.3:h:siemens:en100_ethernet_module_iec_61850:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:en100_ethernet_module_iec_104_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:en100_ethernet_module_iec_104:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:en100_ethernet_module_dnp3_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:en100_ethernet_module_dnp3:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:en100_ethernet_module_modbus_tcp_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:en100_ethernet_module_modbus_tcp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:en100_ethernet_module_profinet_io_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:en100_ethernet_module_profinet_io:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:en100_ethernet_module_iec_61850_firmware:*:*:*:*:*:*:*:* Versions before 4.30 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:en100_ethernet_module_iec_61850:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

  • Fix · CNA EN100 Ethernet module IEC 61850 variant (Siemens AG) Fixed in V4.30
  • Fix · CNA EN100 Ethernet module DNP3 variant (Siemens AG) Fixed in V1.04
  • Fix · CNA EN100 Ethernet module IEC 104 variant (Siemens AG) Fixed in V1.22

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-4838
  2. 2026-10-03 Alias added: GHSA-r849-hjqv-324f

References

  • TI-2018-03417 Missing authentication in Siemens DIGSI 4 CVSS 3.0HIGH 7.5
  • TI-2022-12997 Memory corruption in Siemens EN100 Ethernet module DNP3 IP variant CVSS 3.1HIGH 7.5
  • TI-2018-03416 A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet… CVSS 3.0MEDIUM 5.3

Sources