Read the docs
TI-2018-03421 Aliases CVE-2018-4844GHSA-2w26-vhm9-x8ph

Improper access control in Siemens SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI…

Priority LOW 30CWE-284Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
Low
User interaction
Required
Attack complexity
Low
Impact type
Security bypass, Privilege escalation
Confidentiality · integrity · availability
High · High · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-284 and CWE-269.

Summary

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Why it matters now

EPSS 0.00424 36th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOSSIMATIC WinCC OA UI for Android : All versions < V3.15.10; SIMATIC WinCC OA UI for iOS : All versions < V3.15.10—No fix listedCNA
  • SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS VendorSiemens Affected SIMATIC WinCC OA UI for Android : All versions < V3.15.10; SIMATIC WinCC OA UI for iOS : All versions < V3.15.10 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_wincc_oa_ui:*:*:*:*:*:android:*:*before 3.15.10VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_oa_ui:*:*:*:*:*:iphone_os:*:*before 3.15.10VulnerableSiemens
  • cpe:2.3:a:siemens:simatic_wincc_oa_ui:*:*:*:*:*:android:*:* Versions before 3.15.10 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_oa_ui:*:*:*:*:*:iphone_os:*:* Versions before 3.15.10 Vulnerable ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-4844
  2. 2026-10-03 Alias added: GHSA-2w26-vhm9-x8ph

References

Sources