Read the docs
TI-2018-03952 Aliases CVE-2018-5438GHSA-hmpp-gh47-8r55

Philips ISCV application prior to version 2.3.0 has an insufficient session expiration…

Priority LOW 28CWE-613Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
High
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · None
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-613.

Summary

Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.

Why it matters now

EPSS 0.00437 38th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:philips:intellispace_cardiovascular:*:*:*:*:*:*:*:*up to 2.3.0VulnerablePhilips
  • cpe:2.3:a:philips:intellispace_cardiovascular:*:*:*:*:*:*:*:* Versions up to 2.3.0 Vulnerable ·Philips

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-5438
  2. 2026-10-03 Alias added: GHSA-hmpp-gh47-8r55

References

  • TI-2017-10276 The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and… CVSS 3.0HIGH 7.2
  • TI-2018-10617 Improper privilege management in Philips IntelliSpace Cardiovascular products CVSS 3.1HIGH 7.8
  • TI-2018-10619 In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and… CVSS 3.1MEDIUM 6.7