Improper authentication in Schneider Electric Pelco Sarix Professional
Priority LOW 38CWE-287Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · None
- Fix status
- Fixed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-287.
Summary
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.
Why it matters now
EPSS 0.01331 71st percentileScored 2026-11-07
Fix Fixed Pelco Sarix Professional (Schneider Electric SE): 3.29.76
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Schneider Electric | Pelco Sarix Professional | before 3.29.76 | 3.29.76 | Patch available | CNA |
- Pelco Sarix Professional VendorSchneider Electric Affected before 3.29.76 Fixed in 3.29.76 Patch available CNA
CPE configurations NVD · 40
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:schneider-electric:mps110-1_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:mps110-1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imps110-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imps110-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:ibps110-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:ibps110-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp1110-1_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp1110-1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp1110-1e_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp1110-1e:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
- cpe:2.3:o:schneider-electric:mps110-1_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:mps110-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imps110-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imps110-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:ibps110-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:ibps110-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp1110-1_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp1110-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp1110-1e_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp1110-1e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Show 30 more CPE
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:schneider-electric:imp1110-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp1110-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:ibp1110-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:ibp1110-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp219-1_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp219-1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp219-1e_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp219-1e:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp219-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp219-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:ibp219-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:ibp219-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp319-1_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp319-1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp319-1e_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp319-1e:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:ibp319-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:ibp319-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp519-1_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp519-1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp319-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp319-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp519-1e_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp519-1e:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imp519-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imp519-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:ibp519-1er_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:ibp519-1er:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
| cpe:2.3:o:schneider-electric:imps110-1e_firmware:*:*:*:*:*:*:*:* | before 3.29.67 | Vulnerable | Schneider Electric |
| cpe:2.3:h:schneider-electric:imps110-1e:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Schneider Electric |
- cpe:2.3:o:schneider-electric:imp1110-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp1110-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:ibp1110-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:ibp1110-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp219-1_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp219-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp219-1e_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp219-1e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp219-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp219-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:ibp219-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:ibp219-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp319-1_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp319-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp319-1e_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp319-1e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:ibp319-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:ibp319-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp519-1_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp519-1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp319-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp319-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp519-1e_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp519-1e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imp519-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imp519-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:ibp519-1er_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:ibp519-1er:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
- cpe:2.3:o:schneider-electric:imps110-1e_firmware:*:*:*:*:*:*:*:* Versions before 3.29.67 Vulnerable ·Schneider Electric
- cpe:2.3:h:schneider-electric:imps110-1e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
Remediation
- Fix · CNA Pelco Sarix Professional (Schneider Electric SE) Fixed in 3.29.76
Timeline
- 2026-10-02 Threatist record created from CVE-2018-7236
- 2026-10-03 Alias added: GHSA-9rxc-jvqg-fv36
More Schneider Electric Ibp1110-1er Firmware vulnerabilities
- TI-2018-05247 Buffer overflow in Schneider Electric Pelco Sarix Professional CVSS 3.1CRITICAL 9.8
- TI-2018-05242 Improper input validation in Schneider Electric Pelco Sarix Professional CVSS 3.1CRITICAL 9.8
- TI-2018-05241 Improper input validation in Schneider Electric Pelco Sarix Professional CVSS 3.1CRITICAL 9.8
- TI-2018-05240 Improper input validation in Schneider Electric Pelco Sarix Professional CVSS 3.1CRITICAL 9.8
- TI-2018-05238 Hard-coded credentials in Schneider Electric Pelco Sarix Professional CVSS 3.1CRITICAL 9.8
- TI-2018-05237 Improper authentication in Schneider Electric Pelco Sarix Professional CVSS 3.1CRITICAL 9.8
Sources
- CVE-2018-7236 · CVE Program
- CVE-2018-7236 · NVD
- FIRST EPSS
- GHSA-9rxc-jvqg-fv36 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences