Read the docs
TI-2018-05690 Aliases CVE-2018-7852GHSA-qj59-cxrx-fr36

Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum…

Priority HIGH 72CWE-248Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-248.

Summary

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.03473 89th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Modicon M580 Modicon M340 Modicon Quantum Modicon PremiumModicon M580 Modicon M340 Modicon Quantum Modicon Premium—No fix listedCNA
  • Modicon M580 Modicon M340 Modicon Quantum Modicon Premium Vendor— Affected Modicon M580 Modicon M340 Modicon Quantum Modicon Premium Fixed in — No fix listed CNA

CPE configurations NVD · 8

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-7852
  2. 2026-10-03 Alias added: GHSA-qj59-cxrx-fr36

References

  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05680 Authentication bypass by spoofing in Modicon M580 Modicon M340 Modicon Quantum Modicon… CVSS 3.1CRITICAL 9.8
  • TI-2018-05684 Exposure of resource to wrong sphere in Modicon M580 Modicon M340 Modicon Quantum Modicon… CVSS 3.1CRITICAL 9.8
  • TI-2019-04884 Information disclosure in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum CVSS 3.1HIGH 7.5
  • TI-2019-04843 Missing authentication in Modicon M580 Modicon M340 Modicon Quantum Modicon Premium CVSS 3.1CRITICAL 9.8
  • TI-2018-05685 Improper authentication in Modicon M580 Modicon M340 Modicon Quantum Modicon Premium CVSS 3.1CRITICAL 9.8
See all 38 →

Sources