Read the docs
TI-2018-06395 Aliases CVE-2018-8853GHSA-28xj-6327-x3mf

Improper privilege management in Philips Brilliance CT Scanners

Priority LOW 38CWE-250Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Privilege escalation
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-250.

Summary

Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system.

Why it matters now

EPSS 0.00359 29th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
PhilipsBrilliance CT ScannersBrilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior.—No fix listedCNA
  • Brilliance CT Scanners VendorPhilips Affected Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Fixed in — No fix listed CNA

CPE configurations NVD · 8

CPEVersionsRoleVendor
cpe:2.3:o:philips:brilliance_firmware_64:*:*:*:*:*:*:*:*up to 2.6.2VulnerablePhilips
cpe:2.3:h:philips:brilliance_64:-:*:*:*:*:*:*:*not specified by NVDRunning onPhilips
cpe:2.3:o:philips:brilliance_ict_sp_firmware:*:*:*:*:*:*:*:*up to 3.2.4VulnerablePhilips
cpe:2.3:h:philips:brilliance_ict_sp:-:*:*:*:*:*:*:*not specified by NVDRunning onPhilips
cpe:2.3:o:philips:brilliance_ict_firmware:*:*:*:*:*:*:*:*up to 4.1.6VulnerablePhilips
cpe:2.3:h:philips:brilliance_ict:-:*:*:*:*:*:*:*not specified by NVDRunning onPhilips
cpe:2.3:o:philips:_brilliance_ct_big_bore_firmware:*:*:*:*:*:*:*:*up to 2.3.5VulnerablePhilips
cpe:2.3:h:philips:_brilliance_ct_big_bore:-:*:*:*:*:*:*:*not specified by NVDRunning onPhilips
  • cpe:2.3:o:philips:brilliance_firmware_64:*:*:*:*:*:*:*:* Versions up to 2.6.2 Vulnerable ·Philips
  • cpe:2.3:h:philips:brilliance_64:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Philips
  • cpe:2.3:o:philips:brilliance_ict_sp_firmware:*:*:*:*:*:*:*:* Versions up to 3.2.4 Vulnerable ·Philips
  • cpe:2.3:h:philips:brilliance_ict_sp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Philips
  • cpe:2.3:o:philips:brilliance_ict_firmware:*:*:*:*:*:*:*:* Versions up to 4.1.6 Vulnerable ·Philips
  • cpe:2.3:h:philips:brilliance_ict:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Philips
  • cpe:2.3:o:philips:_brilliance_ct_big_bore_firmware:*:*:*:*:*:*:*:* Versions up to 2.3.5 Vulnerable ·Philips
  • cpe:2.3:h:philips:_brilliance_ct_big_bore:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Philips

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-8853
  2. 2026-10-03 Alias added: GHSA-28xj-6327-x3mf

References

  • TI-2018-06403 Exposure of resource to wrong sphere in Philips Brilliance CT Scanners CVSS 3.0HIGH 8.7
  • TI-2018-06399 Hard-coded credentials in Philips Brilliance CT Scanners CVSS 3.0HIGH 7.8

Sources