Read the docs
TI-2018-08173 Aliases CVE-2018-11448GHSA-g2w7-2wmm-w74m

Cross-site request forgery in Siemens SCALANCE M875

Priority LOW 22CWE-352Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
Required
Attack complexity
Low
Impact type
Tampering, Cross-site scripting
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-352 and CWE-79.

Summary

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Why it matters now

EPSS 0.00317 24th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSCALANCE M875SCALANCE M875 All versions—No fix listedCNA
  • SCALANCE M875 VendorSiemens Affected SCALANCE M875 All versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:siemens:scalance_m875_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:scalance_m875:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:scalance_m875_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:scalance_m875:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-11448
  2. 2026-10-03 Alias added: GHSA-g2w7-2wmm-w74m

References

  • TI-2018-08172 Stack-based buffer overflow in Siemens SCALANCE M875 CVSS 3.0HIGH 8.8
  • TI-2018-03436 OS command injection in Siemens SCALANCE M875 CVSS 3.0HIGH 7.2
  • TI-2018-03435 OS command injection in Siemens SCALANCE M875 CVSS 3.0HIGH 7.2
  • TI-2018-08174 Cross-site scripting in Siemens SCALANCE M875 CVSS 3.0HIGH 7.8
  • TI-2018-03437 Path traversal in Siemens SCALANCE M875 CVSS 3.0MEDIUM 4.9

Sources