Read the docs
TI-2018-08184 Aliases CVE-2018-11459GHSA-x2jv-vf8g-79j6

Protection mechanism failure in Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8…

Priority LOW 34CWE-693Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-693.

Summary

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Why it matters now

EPSS 0.00375 31st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8SINUMERIK 808D V4.7 : All versions; SINUMERIK 808D V4.8 : All versions; SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3—No fix listedCNA
  • SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 VendorSiemens Affected SINUMERIK 808D V4.7 : All versions; SINUMERIK 808D V4.8 : All versions; SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1; SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5; SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 Fixed in — No fix listed CNA

CPE configurations NVD · 10

CPEVersionsRoleVendor
cpe:2.3:o:siemens:sinumerik_808d_v4.7_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:sinumerik_808d_v4.7:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_808d_v4.8_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:sinumerik_808d_v4.8:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*up to 4.7VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_828d_v4.7:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*up to 4.7VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_840d_sl_v4.7:*:*:*:*:*:*:*:*all versionsRunning onSiemens
cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*up to 4.8VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_840d_sl_v4.8:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:sinumerik_808d_v4.7_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_808d_v4.7:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_808d_v4.8_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_808d_v4.8:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:* Versions up to 4.7 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_828d_v4.7:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:* Versions up to 4.7 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_840d_sl_v4.7:*:*:*:*:*:*:*:* Versions all versions Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:* Versions up to 4.8 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_840d_sl_v4.8:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-11459
  2. 2026-10-03 Alias added: GHSA-x2jv-vf8g-79j6

References

  • TI-2018-08191 A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D… CVSS 3.0CRITICAL 9.8
  • TI-2018-08187 Access control flaw in Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D… CVSS 3.0CRITICAL 9.8
  • TI-2018-08190 Out-of-bounds read in Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D… CVSS 3.0HIGH 7.8
  • TI-2018-08188 Stack-based buffer overflow in Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8… CVSS 3.0HIGH 7.8
  • TI-2018-08185 Protection mechanism failure in Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8… CVSS 3.0HIGH 7.8
  • TI-2018-08186 Access control flaw in Siemens SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D… CVSS 3.0MEDIUM 6.6

Sources