Read the docs
TI-2018-10024 Aliases CVE-2018-13813GHSA-q5p9-4pqr-fw9h

Open redirect in Siemens SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor…

Priority LOW 39CWE-601Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Spoofing
Confidentiality · integrity · availability
High · High · None
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-601.

Summary

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Why it matters now

EPSS 0.01681 77th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)SIMATIC HMI Comfort Panels 4" - 22" : All versions < V15 Update 4; SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V15 Update 4; SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4; SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4; SIMATIC WinCC Runtime Professional : All versions < V15 Update 4; SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4; SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions—No fix listedCNA
  • SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) VendorSiemens Affected SIMATIC HMI Comfort Panels 4" - 22" : All versions < V15 Update 4; SIMATIC HMI Comfort Outdoor Panels 7" & 15" : All versions < V15 Update 4; SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V15 Update 4; SIMATIC WinCC Runtime Advanced : All versions < V15 Update 4; SIMATIC WinCC Runtime Professional : All versions < V15 Update 4; SIMATIC WinCC (TIA Portal) : All versions < V15 Update 4; SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions Fixed in — No fix listed CNA

CPE configurations NVD · 23

CPEVersionsRoleVendor
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
Show 13 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):*:*:*:*:*:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*up to 15.0VulnerableSiemens
cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):*:*:*:*:*:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:* Versions up to 15.0 Vulnerable ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-13813
  2. 2026-10-03 Alias added: GHSA-q5p9-4pqr-fw9h

References

  • TI-2021-02413 NULL pointer deref in signature_algorithms processing CVSS 3.1MEDIUM 5.9
  • TI-2019-04626 Information disclosure in Siemens SIMATIC HMI Comfort Panels 4" - 22" CVSS 3.1CRITICAL 9.1
  • TI-2019-04628 Improper handling of exceptional conditions in Siemens SIMATIC CP 443-1 OPC UA CVSS 3.1HIGH 7.5
  • TI-2019-04622 Out-of-bounds read in Siemens SIMATIC CP 1604 CVSS 3.1HIGH 7.5
  • TI-2018-10025 HTTP response splitting in Siemens SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI… CVSS 3.0HIGH 8.8
  • TI-2018-10023 Path traversal in Siemens SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort… CVSS 3.0HIGH 7.5
See all 8 →

Sources