Read the docs
TI-2018-10434 Aliases CVE-2018-14558GHSA-jh5j-w2c9-jcff

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7)…

Priority CRITICAL 100Exploited in the wildCWE-78Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-78.

Summary

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.

Why it matters now

Exploitation Active In CISA KEV since 2021-11-03CISA due date 2022-05-03
EPSS 0.0851 95th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Active
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 6

CPEVersionsRoleVendor
cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*up to 15.03.06.44_cnVulnerableTenda
cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*up to 15.03.05.19\(6318\)_cnVulnerableTenda
cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*up to 15.03.06.23_cnVulnerableTenda
cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:* Versions up to 15.03.06.44_cn Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda
  • cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:* Versions up to 15.03.05.19\(6318\)_cn Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda
  • cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:* Versions up to 15.03.06.23_cn Vulnerable ·Tenda
  • cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2021-11-03 Added to CISA KEV
  2. 2026-10-02 Threatist record created from CVE-2018-14558
  3. 2026-10-03 Alias added: GHSA-jh5j-w2c9-jcff
  4. 2026-10-07 EPSS moved to the 90th–95th percentile
  5. 2026-10-20 EPSS moved to the 95th–99th percentile

References

  • TI-2025-41117 A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda… CVSS 3.1CRITICAL 9.8
  • TI-2025-28844 Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the… CVSS 3.1CRITICAL 9.8
  • TI-2025-19007 Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2. CVSS 3.1CRITICAL 9.8
  • TI-2023-24356 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack… CVSS 3.1CRITICAL 9.8
  • TI-2023-22562 Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01… CVSS 3.1CRITICAL 9.8
  • TI-2023-20197 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0… CVSS 3.1CRITICAL 9.8
See all 91 →

Sources