TI-2018-13445 Aliases CVE-2018-18981GHSA-v3wg-5frm-q7hg

Heap-based buffer overflow in Rockwell Automation FactoryTalk Services Platform v2.90 and…

Priority LOW 39CWE-122Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-122 and the CVSS impact.

Summary

In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.

Why it matters now

EPSS 0.03866 90th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
RockwellRockwell Automation FactoryTalk Services Platform v2.90 and earlierRockwell Automation FactoryTalk Services Platform v2.90 and earlier—No fix listedCNA
  • Rockwell Automation FactoryTalk Services Platform v2.90 and earlier VendorRockwell Affected Rockwell Automation FactoryTalk Services Platform v2.90 and earlier Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*up to 2.90VulnerableRockwell
  • cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:* Versions up to 2.90 Vulnerable ·Rockwell

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-18981
  2. 2026-10-03 Alias added: GHSA-v3wg-5frm-q7hg
  3. 2026-10-14 EPSS moved to the 90th–95th percentile

References

  • TI-2021-05574 Insufficiently protected credentials in Rockwell Automation Studio 5000 Logix Designer… KEVCVSS 3.1CRITICAL 9.8
  • TI-2024-14577 Rockwell Automation FactoryTalk® Service Platform Service Token Vulnerability CVSS 3.1CRITICAL 9.8
  • TI-2020-11367 In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there… CVSS 3.1CRITICAL 10.0
  • TI-2020-05615 Deserialization of untrusted data in Rockwell Automation All versions of FactoryTalk… CVSS 3.1CRITICAL 9.8
  • TI-2023-24910 Rockwell Automation FactoryTalk Services Platform Elevated Privileges Vulnerability CVSS 3.1HIGH 8.1
  • TI-2021-12569 Rockwell Automation FactoryTalk Services Platform Protection Mechanism Failure CVSS 3.1HIGH 8.8
See all 12 →