Read the docs
TI-2018-13672 Aliases CVE-2018-19282GHSA-pf4h-8whx-rxmf

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to…

Priority MEDIUM 51CWE-400Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · NVD. Fix status from CNA. Impact type from CWE-400.

Summary

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.

Why it matters now

EPSS 0.05645 93rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:rockwellautomation:powerflex_525_ac_drives_firmware:*:*:*:*:*:*:*:*up to 5.001VulnerableRockwell
cpe:2.3:h:rockwellautomation:powerflex_525_ac_drives:-:*:*:*:*:*:*:*not specified by NVDRunning onRockwell
  • cpe:2.3:o:rockwellautomation:powerflex_525_ac_drives_firmware:*:*:*:*:*:*:*:* Versions up to 5.001 Vulnerable ·Rockwell
  • cpe:2.3:h:rockwellautomation:powerflex_525_ac_drives:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Rockwell

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2018-19282
  2. 2026-10-03 Alias added: GHSA-pf4h-8whx-rxmf

References

Sources