Read the docs
TI-2019-04848 Aliases CVE-2019-6813GHSA-ffcc-34j7-9r9f

Improper check for unusual conditions in CVE-2019-6813 BMXNOR0200H Ethernet / Serial RTU…

Priority LOW 37CWE-754Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.

Why it matters now

EPSS 0.02084 81st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
CVE-2019-6813BMXNOR0200H Ethernet / Serial RTU moduleall firmware versions—No fix listedCNA
CVE-2019-6813Modicon M340 controllerall firmware versions—No fix listedCNA
  • BMXNOR0200H Ethernet / Serial RTU module VendorCVE-2019-6813 Affected all firmware versions Fixed in — No fix listed CNA
  • Modicon M340 controller VendorCVE-2019-6813 Affected all firmware versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-6813
  2. 2026-10-03 Alias added: GHSA-ffcc-34j7-9r9f

References

  • TI-2018-05250 Hard-coded credentials in Schneider Electric Modicon Premium, Modicon Quantum, Modicon… CVSS 3.0CRITICAL 9.8
  • TI-2018-05604 Improper input validation in Schneider Electric Modicon M340, Modicon Premium, Modicon… CVSS 3.0CRITICAL 9.8
  • TI-2018-05251 Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon… CVSS 3.0CRITICAL 9.8
  • TI-2018-05603 Improper authentication in Schneider Electric Modicon M340, Modicon Premium, Modicon… CVSS 3.0CRITICAL 9.8
  • TI-2019-04845 Improper access control in Schneider Electric BMXNOR0200H Ethernet / Serial RTU module CVSS 3.1HIGH 8.8
  • TI-2017-03927 Uncontrolled resource consumption in Schneider Electric Modicon M340 PLC CVSS 3.0HIGH 7.5
See all 13 →

Sources