Read the docs
TI-2019-04860 Aliases CVE-2019-6827GHSA-w35v-55pp-hj6x

Out-of-bounds write in Interactive Graphical SCADA System Version 14 and prior

Priority LOW 37CWE-787Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.

Summary

A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.

Why it matters now

EPSS 0.01279 70th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Interactive Graphical SCADA System (IGSS) Version 14 and priorInteractive Graphical SCADA System (IGSS) Version 14 and prior—No fix listedCNA
  • Interactive Graphical SCADA System (IGSS) Version 14 and prior Vendor— Affected Interactive Graphical SCADA System (IGSS) Version 14 and prior Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*up to 12.0; 13.0 to before 13.0.0.19140; 14.0 to before 14.0.0.19120VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:* Versions up to 12.0; 13.0 to before 13.0.0.19140; 14.0 to before 14.0.0.19120 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-6827
  2. 2026-10-03 Alias added: GHSA-w35v-55pp-hj6x

References

  • TI-2013-00550 Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System… CVSS 2.0HIGH 10.0
  • TI-2022-02151 Integer overflow in Schneider Electric IGSS Data Server CVSS 3.1CRITICAL 9.8
  • TI-2022-14164 Buffer overflow in Schneider Electric IGSS Data Server CVSS 3.1CRITICAL 9.8
  • TI-2022-14162 Buffer overflow in Schneider Electric IGSS Data Server CVSS 3.1CRITICAL 9.8
  • TI-2022-14161 Buffer overflow in Schneider Electric IGSS Data Server CVSS 3.1CRITICAL 9.8
  • TI-2022-14160 Buffer overflow in Schneider Electric IGSS Data Server CVSS 3.1CRITICAL 9.8
See all 42 →