Read the docs
TI-2019-04875 Aliases CVE-2019-6842GHSA-c474-f694-3xx6

Improper handling of exceptional conditions in Modicon M580, Modicon M340, and Modicon…

Priority LOW 24CWE-755Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.

Why it matters now

EPSS 0.00959 61st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info)—No fix listedCNA
  • Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Vendor— Affected Modicon M580, Modicon M340, and Modicon BMxCRA / 140CRA modules (see notification for version info) Fixed in — No fix listed CNA

CPE configurations NVD · 8

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_bmxcra_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_bmxcra:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_140cra_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_140cra:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_bmxcra_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_bmxcra:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_140cra_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_140cra:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-6842
  2. 2026-10-03 Alias added: GHSA-c474-f694-3xx6

References

  • TI-2019-04874 Improper handling of exceptional conditions in Modicon M580, Modicon M340, and Modicon… CVSS 3.1MEDIUM 4.9
  • TI-2019-04879 Cleartext transmission of sensitive information in Modicon M580, Modicon M340, Modicon… CVSS 3.1MEDIUM 6.5
  • TI-2019-04880 Improper handling of exceptional conditions in Modicon M580, Modicon M340, and Modicon… CVSS 3.1MEDIUM 4.9
  • TI-2019-04877 Improper handling of exceptional conditions in Modicon M580, Modicon M340, and Modicon… CVSS 3.1MEDIUM 4.9
  • TI-2019-04876 Improper handling of exceptional conditions in Modicon M580, Modicon M340, and Modicon… CVSS 3.1MEDIUM 4.9

Sources