Read the docs
TI-2019-04894 Aliases CVE-2019-6957GHSA-rmfq-rhp2-gvm9

Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems

Priority MEDIUM 46CWE-787Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.

Summary

A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.

Why it matters now

EPSS 0.01988 80th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 25

CPEVersionsRoleVendor
cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*3.0 – 3.7VulnerableBosch
cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*before 1.7.6.079VulnerableBosch
cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*up to 9.0VulnerableBosch
cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*2.2 – 4.4VulnerableBosch
cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*4.5VulnerableBosch
cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*4.6VulnerableBosch
cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*4.6.1VulnerableBosch
cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*before 6.10VulnerableBosch
cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*before 3.71.0032; 3.81 to before 3.81.0048VulnerableBosch
cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*before 6.32.0099VulnerableBosch
  • cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:* Versions 3.0 – 3.7 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:* Versions before 1.7.6.079 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:* Versions up to 9.0 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:* Versions 2.2 – 4.4 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:* Versions 4.5 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:* Versions 4.6 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:* Versions 4.6.1 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:* Versions before 6.10 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:* Versions before 3.71.0032; 3.81 to before 3.81.0048 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:* Versions before 6.32.0099 Vulnerable ·Bosch
Show 15 more CPE
CPEVersionsRoleVendor
cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*before 6.43.0023; 6.45 to before 6.45.0008VulnerableBosch
cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*before 0380.037VulnerableBosch
cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableBosch
cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*before 038.037VulnerableBosch
cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableBosch
cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*gen1Running onBosch
cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*gen2Running onBosch
cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*2.1.8.5VulnerableBosch
cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*2.1.9.0VulnerableBosch
cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*2.1.9.1VulnerableBosch
cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*2.1.9.3VulnerableBosch
cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
  • cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:* Versions before 6.43.0023; 6.45 to before 6.45.0008 Vulnerable ·Bosch
  • cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:* Versions before 0380.037 Vulnerable ·Bosch
  • cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Bosch
  • cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:* Versions before 038.037 Vulnerable ·Bosch
  • cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Bosch
  • cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:* Versions gen1 Running on ·Bosch
  • cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:* Versions gen2 Running on ·Bosch
  • cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:* Versions 2.1.8.5 Vulnerable ·Bosch
  • cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:* Versions 2.1.9.0 Vulnerable ·Bosch
  • cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:* Versions 2.1.9.1 Vulnerable ·Bosch
  • cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:* Versions 2.1.9.3 Vulnerable ·Bosch
  • cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-6957
  2. 2026-10-03 Alias added: GHSA-rmfq-rhp2-gvm9

References

  • TI-2019-04895 Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems CVSS 3.1CRITICAL 9.1
  • TI-2021-06222 Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products CVSS 3.1CRITICAL 9.1

Sources