Information disclosure in AndroVideo Advan VD-1 firmware
Priority MEDIUM 46CWE-200Published · Updated
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Information disclosure, Security bypass
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-200 and CWE-287.
Summary
A vulnerability of remote credential disclosure was discovered in Advan VD-1 firmware versions up to 230. An attacker can export system configuration which is not encrypted to get the administrator’s account and password in plain text via cgibin/ExportSettings.cgi?Export=1 without any authentication.
Why it matters now
EPSS 0.01942 80th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| AndroVideo | Advan VD-1 firmware | up to 230 | — | No fix listed | CNA |
- Advan VD-1 firmware VendorAndroVideo Affected up to 230 Fixed in — No fix listed CNA
CPE configurations NVD · 6
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:androvideo:vd_1_firmware:*:*:*:*:*:*:*:* | up to 230 | Vulnerable | AndroVideo |
| cpe:2.3:h:androvideo:vd_1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | AndroVideo |
| cpe:2.3:o:geovision:gv-vr360_firmware:*:*:*:*:*:*:*:* | up to 1.10 | Vulnerable | GeoVision |
| cpe:2.3:h:geovision:gv-vr360:-:*:*:*:*:*:*:* | not specified by NVD | Running on | GeoVision |
| cpe:2.3:o:geovision:gv-vd8700_firmware:*:*:*:*:*:*:*:* | up to 1.01 | Vulnerable | GeoVision |
| cpe:2.3:h:geovision:gv-vd8700:-:*:*:*:*:*:*:* | not specified by NVD | Running on | GeoVision |
- cpe:2.3:o:androvideo:vd_1_firmware:*:*:*:*:*:*:*:* Versions up to 230 Vulnerable ·AndroVideo
- cpe:2.3:h:androvideo:vd_1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·AndroVideo
- cpe:2.3:o:geovision:gv-vr360_firmware:*:*:*:*:*:*:*:* Versions up to 1.10 Vulnerable ·GeoVision
- cpe:2.3:h:geovision:gv-vr360:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·GeoVision
- cpe:2.3:o:geovision:gv-vd8700_firmware:*:*:*:*:*:*:*:* Versions up to 1.01 Vulnerable ·GeoVision
- cpe:2.3:h:geovision:gv-vd8700:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·GeoVision
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2019-11064
- 2026-10-03 Alias added: GHSA-3q8h-2vx4-hg56
References
More AndroVideo Vd 1 Firmware vulnerabilities
- TI-2019-10074 Advan VD-1 allows a remote user to enable Android Debug Bridge without any authentication CVSS 3.0CRITICAL 9.8
- TI-2019-10077 Advan VD-1 allows users to download arbitrary files CVSS 3.1HIGH 7.5
- TI-2019-10075 Advan VD-1 has a vulnerability that allows remote arbitrary APK installation CVSS 3.0HIGH 7.5
- TI-2019-10076 Advan VD-1 has a reflected XSS vulnerability in page cgibin/ssi.cgi CVSS 3.0MEDIUM 6.1
Sources
- CVE-2019-11064 · CVE Program
- CVE-2019-11064 · NVD
- FIRST EPSS
- GHSA-3q8h-2vx4-hg56 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences