Read the docs
TI-2019-10189 Aliases CVE-2019-13557GHSA-q62p-7qmj-cm9r

Information disclosure in Tasy EMR

Priority LOW 26CWE-200Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
Low · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-200.

Summary

In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.

Why it matters now

EPSS 0.01154 67th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Tasy EMRTasy WebPortal Versions 3.02.1757 and prior.—No fix listedCNA
  • Tasy EMR Vendor— Affected Tasy WebPortal Versions 3.02.1757 and prior. Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:philips:tasy_emr:*:*:*:*:*:*:*:*up to 3.02.1744VulnerablePhilips
cpe:2.3:a:philips:tasy_webportal:*:*:*:*:*:*:*:*up to 3.02.1757VulnerablePhilips
  • cpe:2.3:a:philips:tasy_emr:*:*:*:*:*:*:*:* Versions up to 3.02.1744 Vulnerable ·Philips
  • cpe:2.3:a:philips:tasy_webportal:*:*:*:*:*:*:*:* Versions up to 3.02.1757 Vulnerable ·Philips

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-13557
  2. 2026-10-03 Alias added: GHSA-q62p-7qmj-cm9r

References

  • TI-2019-04616 Cross-site scripting in Philips Tasy EMR CVSS 3.1MEDIUM 5.4

Sources