Read the docs
TI-2019-11130 Aliases CVE-2019-14931GHSA-hx46-fxf5-4hff

An issue was discovered on Mitsubishi Electric Europe B.V.

Priority HIGH 76CWE-78Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-78.

Summary

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell. Functionality in mobile.php provides users with the ability to ping sites or IP addresses via Mobile Connection Test. When the Mobile Connection Test is submitted, action.php is called to execute the test. An attacker can use a shell command separator (;) in the host variable to execute operating system commands upon submitting the test data.

Why it matters now

EPSS 0.57376 99th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*up to 2.02VulnerableMitsubishi Electric Europe B.V.
cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*not specified by NVDRunning onMitsubishi Electric Europe B.V.
cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*up to 3.0VulnerableINEA
cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*not specified by NVDRunning onINEA
  • cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:* Versions up to 2.02 Vulnerable ·Mitsubishi Electric Europe B.V.
  • cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Mitsubishi Electric Europe B.V.
  • cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:* Versions up to 3.0 Vulnerable ·INEA
  • cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·INEA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-14931
  2. 2026-10-03 Alias added: GHSA-hx46-fxf5-4hff