Read the docs
TI-2019-13914 Aliases CVE-2019-19294GHSA-p4mj-wj62-mjr9

Cross-site scripting in Siemens Control Center Server

Priority LOW 30CWE-79Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
None
Attack complexity
High
Impact type
Cross-site scripting
Confidentiality · integrity · availability
None · High · None
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-79.

Summary

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains multiple stored Cross-site Scripting (XSS) vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code into the CCS web application that is later executed in the browser context of any other user who views the relevant CCS web content.

Why it matters now

EPSS 0.0101 63rd percentileScored 2026-11-07
Fix Fixed Control Center Server (CCS) (Siemens): V1.5.0

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensControl Center Server (CCS)before V1.5.0V1.5.0Patch availableCNA
  • Control Center Server (CCS) VendorSiemens Affected before V1.5.0 Fixed in V1.5.0 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
  • cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens

Remediation

  • Fix · CNA Control Center Server (CCS) (Siemens) Fixed in V1.5.0

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-19294
  2. 2026-10-03 Alias added: GHSA-p4mj-wj62-mjr9

References

  • TI-2019-13345 Improper authentication in Siemens Control Center Server CVSS 3.1CRITICAL 9.8
  • TI-2019-13347 Missing authentication in Siemens SiNVR/SiVMS Video Server CVSS 3.1CRITICAL 9.8
  • TI-2019-13912 SQL injection in Siemens Control Center Server CVSS 3.1HIGH 8.8
  • TI-2019-13916 Path traversal in Siemens SiNVR/SiVMS Video Server CVSS 3.1HIGH 8.1
  • TI-2019-13346 Path traversal in Siemens Control Center Server CVSS 3.1HIGH 7.7
  • TI-2019-13917 Path traversal in Siemens SiNVR/SiVMS Video Server CVSS 3.1HIGH 7.5
See all 13 →

Sources