Uncontrolled resource consumption in Siemens Development/Evaluation Kits for PROFINET IO…
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Denial of service
- Confidentiality · integrity · availability
- None · None · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-400.
Summary
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET 200eco PN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET 200eco PN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | all versions | — | No fix listed | CNA |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | all versions | — | No fix listed | CNA |
| Siemens | KTK ATE530S | all versions | — | No fix listed | CNA |
| Siemens | SIDOOR ATD430W | all versions | — | No fix listed | CNA |
| Siemens | SIDOOR ATE530S COATED | all versions | — | No fix listed | CNA |
| Siemens | SIDOOR ATE531S | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200AL IM 157-1 PN | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, DI 16x24VDC, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, DI 8x24VDC, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L | V5.1.1 to before V5.1.3 | V5.1.3 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L | V5.1.1 to before V5.1.2 | V5.1.2 | Patch available | CNA |
| Siemens | SIMATIC ET 200MP IM 155-5 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200pro IM 154-8 PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200pro IM 154-8F PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200pro IM 154-8FX PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200S IM 151-8 PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200S IM 151-8F PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200SP IM 155-6 MF HF | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200SP IM 155-6 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200SP IM 155-6 PN/2 HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200SP IM 155-6 PN/3 HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) | before V2.0 | V2.0 | Patch available | CNA |
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) | before V2.0 | V2.0 | Patch available | CNA |
| Siemens | SIMATIC MICRO-DRIVE PDC | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC PN/MF Coupler | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC PN/PN Coupler | All versions >= V4.2 | — | No fix listed | CNA |
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) | before V4.4.0 | V4.4.0 | Patch available | CNA |
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants) | before V2.0 | V2.0 | Patch available | CNA |
| Siemens | SIMATIC S7-1500 Software Controller | before V2.0 | V2.0 | Patch available | CNA |
| Siemens | SIMATIC S7-300 CPU 314C-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 315-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 315F-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 315T-3 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 317-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 317F-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 317T-3 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 317TF-3 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 319-3 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-300 CPU 319F-3 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants) | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) | before V10.2 | V10.2 | Patch available | CNA |
| Siemens | SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) | before V8.3 | V8.3 | Patch available | CNA |
| Siemens | SIMATIC TDC CP51M1 | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC TDC CPU555 | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC WinAC RTX 2010 | all versions | — | No fix listed | CNA |
| Siemens | SIMATIC WinAC RTX F 2010 | all versions | — | No fix listed | CNA |
| Siemens | SINAMICS S/G Control Unit w. PROFINET | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200S IM 151-8 PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200S IM 151-8F PN/DP CPU | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF TX RAIL | V4.2.0 and later | — | No fix listed | CNA |
| Siemens | SIPLUS NET PN/PN Coupler | All versions >= V4.2 | — | No fix listed | CNA |
| Siemens | SIPLUS S7-300 CPU 314C-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS S7-300 CPU 315-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS S7-300 CPU 315F-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS S7-300 CPU 317-2 PN/DP | all versions | — | No fix listed | CNA |
| Siemens | SIPLUS S7-300 CPU 317F-2 PN/DP | all versions | — | No fix listed | CNA |
- Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P VendorSiemens Affected all versions Fixed in — No fix listed CNA
- KTK ATE530S VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIDOOR ATD430W VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIDOOR ATE530S COATED VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIDOOR ATE531S VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200AL IM 157-1 PN VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, DI 16x24VDC, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, DI 8x24VDC, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L VendorSiemens Affected V5.1.1 to before V5.1.3 Fixed in V5.1.3 Patch available CNA
- SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L VendorSiemens Affected V5.1.1 to before V5.1.2 Fixed in V5.1.2 Patch available CNA
- SIMATIC ET 200MP IM 155-5 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIMATIC ET 200pro IM 154-8 PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200pro IM 154-8F PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200pro IM 154-8FX PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200S IM 151-8 PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200S IM 151-8F PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200SP IM 155-6 MF HF VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC ET 200SP IM 155-6 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIMATIC ET 200SP IM 155-6 PN/2 HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIMATIC ET 200SP IM 155-6 PN/3 HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) VendorSiemens Affected before V2.0 Fixed in V2.0 Patch available CNA
- SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) VendorSiemens Affected before V2.0 Fixed in V2.0 Patch available CNA
- SIMATIC MICRO-DRIVE PDC VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC PN/MF Coupler VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC PN/PN Coupler VendorSiemens Affected All versions >= V4.2 Fixed in — No fix listed CNA
- SIMATIC S7-1200 CPU family (incl. SIPLUS variants) VendorSiemens Affected before V4.4.0 Fixed in V4.4.0 Patch available CNA
- SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants) VendorSiemens Affected before V2.0 Fixed in V2.0 Patch available CNA
- SIMATIC S7-1500 Software Controller VendorSiemens Affected before V2.0 Fixed in V2.0 Patch available CNA
- SIMATIC S7-300 CPU 314C-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 315-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 315F-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 315T-3 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 317-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 317F-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 317T-3 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 317TF-3 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 319-3 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-300 CPU 319F-3 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants) VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) VendorSiemens Affected before V10.2 Fixed in V10.2 Patch available CNA
- SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) VendorSiemens Affected before V8.3 Fixed in V8.3 Patch available CNA
- SIMATIC TDC CP51M1 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC TDC CPU555 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC WinAC RTX 2010 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIMATIC WinAC RTX F 2010 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SINAMICS S/G Control Unit w. PROFINET VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS ET 200MP IM 155-5 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200MP IM 155-5 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200S IM 151-8 PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS ET 200S IM 151-8F PN/DP CPU VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS ET 200SP IM 155-6 PN HF TX RAIL VendorSiemens Affected V4.2.0 and later Fixed in — No fix listed CNA
- SIPLUS NET PN/PN Coupler VendorSiemens Affected All versions >= V4.2 Fixed in — No fix listed CNA
- SIPLUS S7-300 CPU 314C-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS S7-300 CPU 315-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS S7-300 CPU 315F-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS S7-300 CPU 317-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
- SIPLUS S7-300 CPU 317F-2 PN/DP VendorSiemens Affected all versions Fixed in — No fix listed CNA
CPE configurations NVD · 65
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:siemens:ktk_ate530s_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:ktk_ate530s:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:sidoor_atd430w_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:sidoor_atd430w:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:sidoor_ate530s_coated_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:sidoor_ate530s_coated:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:sidoor_ate531s_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:sidoor_ate531s:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
- cpe:2.3:o:siemens:ktk_ate530s_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:ktk_ate530s:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:sidoor_atd430w_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:sidoor_atd430w:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:sidoor_ate530s_coated_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:sidoor_ate530s_coated:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:sidoor_ate531s_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:sidoor_ate531s:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
Show 55 more CPE
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_hf_firmware:*:*:*:*:*:*:*:* | up to 4.2 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_hf:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_et200sp_im155-6_mf_hf_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et200sp_im155-6_mf_hf:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_ha_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_ha:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_hf_firmware:*:*:*:*:*:*:*:* | up to 4.2 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_hf:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn\/2_hf_firmware:*:*:*:*:*:*:*:* | up to 4.2 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn\/2_hf:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_micro-drive_pdc_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_micro-drive_pdc:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_pn\/pn_coupler_firmware:*:*:*:*:*:*:*:* | up to 4.2 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_pn\/pn_coupler:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:* | before 2.0 | Vulnerable | Siemens |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-400_pn\/dp:v7:*:*:*:*:*:*:* | v7 | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_s7-410_cpu:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_2010_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:simatic_winac_rtx_\(f\)_2010:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
| cpe:2.3:o:siemens:sinamics_s\/g_control_unit_firmware:*:*:*:*:*:*:*:* | all versions | Vulnerable | Siemens |
| cpe:2.3:h:siemens:sinamics_s\/g_control_unit:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Siemens |
- cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_hf_firmware:*:*:*:*:*:*:*:* Versions up to 4.2 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_hf:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_et200sp_im155-6_mf_hf_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et200sp_im155-6_mf_hf:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_ha_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_ha:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_hf_firmware:*:*:*:*:*:*:*:* Versions up to 4.2 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_hf:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn\/2_hf_firmware:*:*:*:*:*:*:*:* Versions up to 4.2 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn\/2_hf:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_micro-drive_pdc_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_micro-drive_pdc:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_pn\/pn_coupler_firmware:*:*:*:*:*:*:*:* Versions up to 4.2 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_pn\/pn_coupler:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\/dp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\/dp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\/dp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\/dp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\/dp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\/dp:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:* Versions before 2.0 Vulnerable ·Siemens
- cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-400_pn\/dp:v7:*:*:*:*:*:*:* Versions v7 Running on ·Siemens
- cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_s7-410_cpu:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:simatic_winac_rtx_\(f\)_2010_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:simatic_winac_rtx_\(f\)_2010:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
- cpe:2.3:o:siemens:sinamics_s\/g_control_unit_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
- cpe:2.3:h:siemens:sinamics_s\/g_control_unit:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
Remediation
- Fix · CNA SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, CM 4x IO-Link, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, CM 8x IO-Link, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, DI 16x24VDC, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, DI 8x24VDC, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, DIQ 16x24VDC/2A, M12-L (Siemens) Fixed in V5.1.3
- Fix · CNA SIMATIC ET 200eco PN, DQ 8x24VDC/0,5A, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200eco PN, DQ 8x24VDC/2A, M12-L (Siemens) Fixed in V5.1.2
- Fix · CNA SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (Siemens) Fixed in V2.0
- Fix · CNA SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (Siemens) Fixed in V2.0
- Fix · CNA SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Siemens) Fixed in V4.4.0
- Fix · CNA SIMATIC S7-1500 CPU family (incl. related ET 200 CPUs and SIPLUS variants) (Siemens) Fixed in V2.0
- Fix · CNA SIMATIC S7-1500 Software Controller (Siemens) Fixed in V2.0
- Fix · CNA SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (Siemens) Fixed in V10.2
- Fix · CNA SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (Siemens) Fixed in V8.3
Timeline
- 2026-10-02 Threatist record created from CVE-2019-19300
- 2026-10-03 Alias added: GHSA-vwm3-cv6h-hrm3
References
Sources
- CVE-2019-19300 · CVE Program
- CVE-2019-19300 · NVD
- FIRST EPSS
- GHSA-vwm3-cv6h-hrm3 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences