Read the docs
TI-2019-14414 Aliases CVE-2019-19986GHSA-29pj-p885-q429

An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29.

Priority LOW 36CWE-89Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
SQL injection
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-89.

Summary

An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. An attacker without authentication is able to execute arbitrary SQL SELECT statements by injecting the HTTP (POST or GET) parameter persoid into /tools/VamPersonPhoto.php. The SQL Injection type is Error-based (this means that relies on error messages thrown by the database server to obtain information about the structure of the database).

Why it matters now

EPSS 0.01334 71st percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:seling:visual_access_manager:*:*:*:*:*:*:*:*4.15.0 – 4.29.0VulnerableSeling
  • cpe:2.3:a:seling:visual_access_manager:*:*:*:*:*:*:*:* Versions 4.15.0 – 4.29.0 Vulnerable ·Seling

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-19986
  2. 2026-10-03 Alias added: GHSA-29pj-p885-q429

References

  • TI-2019-14422 An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. CVSS 3.1CRITICAL 9.8
  • TI-2019-14416 An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. CVSS 3.1HIGH 8.8
  • TI-2023-22536 An issue was discovered in Selesta Visual Access Manager (VAM) prior to 4.42.2. CVSS 3.1HIGH 8.8
  • TI-2019-14417 An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. CVSS 3.1HIGH 7.5
  • TI-2023-22540 An issue was discovered in Selesta Visual Access Manager (VAM) prior to 4.42.2. CVSS 3.1MEDIUM 6.5
  • TI-2019-14420 An issue was discovered in Selesta Visual Access Manager (VAM) 4.15.0 through 4.29. CVSS 3.1MEDIUM 6.5
See all 25 →

Sources