Read the docs
TI-2020-04571 Aliases CVE-2020-5602GHSA-258g-4g7h-f495

XML external entity injection in Mitsubishi Electoric FA Engineering Software

Priority LOW 36CWE-611Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-611 and the CVSS impact.

Summary

Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.

Why it matters now

EPSS 0.01431 73rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Mitsubishi Electric CorporationMitsubishi Electoric FA Engineering SoftwareCPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier—No fix listedCNA
  • Mitsubishi Electoric FA Engineering Software VendorMitsubishi Electric Corporation Affected CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier Fixed in — No fix listed CNA

CPE configurations NVD · 20

CPEVersionsRoleVendor
cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*up to 1.94yVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*up to 1.010lVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*up to 1.010lVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*up to 1.221fVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*up to 1.100eVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*up to 1.590qVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*up to 1.060nVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*up to 1.01bVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*up to 1.03dVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*up to 4.4VulnerableMitsubishi Electric Europe B.V.
Show 10 more CPE
CPEVersionsRoleVendor
cpe:2.3:a:mitsubishielectric:melsec-l_flexible_high-speed_i\/o_control_module_configuration_tool:*:*:*:*:*:*:*:*up to 1.005fVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*up to 1.04eVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*up to 1.14qVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*up to 2.62qVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*up to 1.004eVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*up to 1.006gVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*up to 1.100eVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*up to 1.160sVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*up to 3.73bVulnerableMitsubishi Electric Europe B.V.
cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*up to 1.60nVulnerableMitsubishi Electric Europe B.V.

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-5602
  2. 2026-10-03 Alias added: GHSA-258g-4g7h-f495

References

  • TI-2022-14737 Deserialization of untrusted data in Mitsubishi Electric Corporation GENESIS64 CVSS 3.1CRITICAL 9.8
  • TI-2022-19113 Authentication Bypass Vulnerability in Web Server Function on MELSEC Series CVSS 3.1CRITICAL 9.1
  • TI-2023-01345 Denial-of-Service and Remote Code Execution Vulnerability in MELSEC Series CPU module CVSS 3.1CRITICAL 10.0
  • TI-2023-06346 Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')… CVSS 3.1CRITICAL 9.8
  • TI-2023-03131 Denial of Service (DoS) and Remote Code Execution Vulnerability in MITSUBISHI CNC Series CVSS 3.1CRITICAL 9.8
  • TI-2021-03821 Memory corruption in Mitsubishi Electric Corporation CPU Module Logging Configuration Tool CVSS 3.1CRITICAL 9.8
See all 151 →