Read the docs
TI-2020-06048 Aliases CVE-2020-7525GHSA-h2g8-f7wg-mhxh

Missing brute-force protection in All hardware versions of spaceLYnk and Wiser for KNX

Priority LOW 36CWE-307Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-307.

Summary

Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used.

Why it matters now

EPSS 0.01484 74th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—All hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk)All hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk)—No fix listedCNA
  • All hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) Vendor— Affected All hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) Fixed in — No fix listed CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*before 2.5.1VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*before 2.5.1VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:* Versions before 2.5.1 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:* Versions before 2.5.1 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-7525
  2. 2026-10-03 Alias added: GHSA-h2g8-f7wg-mhxh

References

  • TI-2022-07054 Missing brute-force protection in spaceLYnk , Wiser for KNX , fellerLYnk CVSS 3.1CRITICAL 9.8
  • TI-2021-05618 Missing brute-force protection in homeLYnk and spaceLYnk V2.60 and prior CVSS 3.1CRITICAL 9.8
  • TI-2021-05619 Broken or risky cryptographic algorithm in homeLYnk and spaceLYnk V2.60 and prior CVSS 3.1CRITICAL 9.8
  • TI-2019-04865 Improper authentication in Schneider Electric spaceLYnk CVSS 3.1HIGH 8.3
  • TI-2018-05621 In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and… CVSS 3.0HIGH 7.5
  • TI-2022-07055 Cross-site request forgery in spaceLYnk , Wiser for KNX , fellerLYnk CVSS 3.1HIGH 8.1
See all 16 →

Sources