Read the docs
TI-2020-06104 Aliases CVE-2020-7581GHSA-6pc5-ccr3-mpqp

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2)…

Priority LOW 30CWE-428Published · Updated

Key facts

Attack vector
Local
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-428.

Summary

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Why it matters now

EPSS 0.00379 32nd percentileScored 2026-11-07
Fix Fixed Opcenter Execution Discrete (Siemens): V3.2Opcenter Execution Foundation (Siemens): V3.2+3 more products

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensOpcenter Execution Discretebefore V3.2V3.2Patch availableCNA
SiemensOpcenter Execution Foundationbefore V3.2V3.2Patch availableCNA
SiemensOpcenter Execution Processbefore V3.2V3.2Patch availableCNA
SiemensOpcenter Intelligencebefore V3.3V3.3Patch availableCNA
SiemensOpcenter Qualitybefore V11.3V11.3Patch availableCNA
SiemensOpcenter RD&LV8.0—No fix listedCNA
SiemensSIMATIC Notifier Server for WindowsAll versions—No fix listedCNA
SiemensSIMATIC PCS neoAll versions < V3.0 SP1—No fix listedCNA
SiemensSIMATIC STEP 7 (TIA Portal) V15All versions < V15.1 Update 5—No fix listedCNA
SiemensSIMATIC STEP 7 (TIA Portal) V16All versions < V16 Update 2—No fix listedCNA
SiemensSIMOCODE ES V15.1All versions < V15.1 Update 4—No fix listedCNA
SiemensSIMOCODE ES V16All versions < V16 Update 1—No fix listedCNA
SiemensSoft Starter ES V15.1All versions < V15.1 Update 3—No fix listedCNA
SiemensSoft Starter ES V16All versions < V16 Update 1—No fix listedCNA
  • Opcenter Execution Discrete VendorSiemens Affected before V3.2 Fixed in V3.2 Patch available CNA
  • Opcenter Execution Foundation VendorSiemens Affected before V3.2 Fixed in V3.2 Patch available CNA
  • Opcenter Execution Process VendorSiemens Affected before V3.2 Fixed in V3.2 Patch available CNA
  • Opcenter Intelligence VendorSiemens Affected before V3.3 Fixed in V3.3 Patch available CNA
  • Opcenter Quality VendorSiemens Affected before V11.3 Fixed in V11.3 Patch available CNA
  • Opcenter RD&L VendorSiemens Affected V8.0 Fixed in — No fix listed CNA
  • SIMATIC Notifier Server for Windows VendorSiemens Affected All versions Fixed in — No fix listed CNA
  • SIMATIC PCS neo VendorSiemens Affected All versions < V3.0 SP1 Fixed in — No fix listed CNA
  • SIMATIC STEP 7 (TIA Portal) V15 VendorSiemens Affected All versions < V15.1 Update 5 Fixed in — No fix listed CNA
  • SIMATIC STEP 7 (TIA Portal) V16 VendorSiemens Affected All versions < V16 Update 2 Fixed in — No fix listed CNA
  • SIMOCODE ES V15.1 VendorSiemens Affected All versions < V15.1 Update 4 Fixed in — No fix listed CNA
  • SIMOCODE ES V16 VendorSiemens Affected All versions < V16 Update 1 Fixed in — No fix listed CNA
  • Soft Starter ES V15.1 VendorSiemens Affected All versions < V15.1 Update 3 Fixed in — No fix listed CNA
  • Soft Starter ES V16 VendorSiemens Affected All versions < V16 Update 1 Fixed in — No fix listed CNA

CPE configurations NVD · 13

CPEVersionsRoleVendor
cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*before 3.2VulnerableSiemens
cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*before 3.2VulnerableSiemens
cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*before 3.2VulnerableSiemens
cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*before 11.3VulnerableSiemens
cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*8.0VulnerableSiemens
cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*all versionsVulnerableSiemens
cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*before 16VulnerableSiemens
cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*16VulnerableSiemens
  • cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* Versions before 3.2 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* Versions before 3.2 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* Versions before 3.2 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* Versions before 11.3 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:* Versions 8.0 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* Versions before 16 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:* Versions 16 Vulnerable ·Siemens
Show 3 more CPE
CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*16 update1VulnerableSiemens
cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*all versionsVulnerableSiemens
  • cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:* Versions 16 update1 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens
  • cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Siemens

Remediation

  • Fix · CNA Opcenter Execution Discrete (Siemens) Fixed in V3.2
  • Fix · CNA Opcenter Execution Foundation (Siemens) Fixed in V3.2
  • Fix · CNA Opcenter Execution Process (Siemens) Fixed in V3.2
  • Fix · CNA Opcenter Intelligence (Siemens) Fixed in V3.3
  • Fix · CNA Opcenter Quality (Siemens) Fixed in V11.3

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-7581
  2. 2026-10-03 Alias added: GHSA-6pc5-ccr3-mpqp

References

  • TI-2020-06109 Uncontrolled resource consumption in Siemens Opcenter Execution Discrete CVSS 3.1HIGH 8.2
  • TI-2020-06110 Improper input validation in Siemens Opcenter Execution Discrete CVSS 3.1MEDIUM 5.3

Sources