Read the docs
TI-2020-06562 Aliases CVE-2020-8144GHSA-8vc5-gg9h-3rv8

Path traversal in UniFi Video Controller

Priority LOW 38CWE-22Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

The UniFi Video Server v3.9.3 and prior (for Windows 7/8/10 x64) web interface Firmware Update functionality, under certain circumstances, does not validate firmware download destinations to ensure they are within the intended destination directory tree. It accepts a request with a URL to firmware update information. If the version field contains ..\ character sequences, the destination file path to save the firmware can be manipulated to be outside the intended destination directory tree. Fixed in UniFi Video Controller v3.10.3 and newer.

Why it matters now

EPSS 0.00748 55th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—UniFi Video Controller (for Windows 7/8/10 x64)v3.9.3 and prior are affected; Fixed in v3.10.3 and newer—No fix listedCNA
  • UniFi Video Controller (for Windows 7/8/10 x64) Vendor— Affected v3.9.3 and prior are affected; Fixed in v3.10.3 and newer Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:ui:unifi_video:*:*:*:*:*:*:*:*up to 3.9.3VulnerableUbiquiti
cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*not specified by NVDRunning onMicrosoft
  • cpe:2.3:a:ui:unifi_video:*:*:*:*:*:*:*:* Versions up to 3.9.3 Vulnerable ·Ubiquiti
  • cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Microsoft

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-8144
  2. 2026-10-03 Alias added: GHSA-8vc5-gg9h-3rv8

References

  • TI-2019-03839 Cross-site request forgery in UniFi Video Server CVSS 3.0HIGH 8.8
  • TI-2016-05937 Ubiquiti UniFi Video before 3.8.0 for Windows uses weak permissions for the installation… CVSS 3.1HIGH 7.8
  • TI-2020-15188 In Ubiquiti UniFi Video v3.10.13, when the executable starts, its first library… CVSS 3.1HIGH 7.8
  • TI-2020-06564 Uncontrolled search path in UniFi Video Controller CVSS 3.1HIGH 7.8
  • TI-2020-06563 The UniFi Video Server (Windows) web interface configuration restore functionality at the… CVSS 3.1MEDIUM 6.5
  • TI-2014-01761 The default Flash cross-domain policy (crossdomain.xml) in Ubiquiti Networks UniFi Video… CVSS 2.0MEDIUM 6.0

Sources