Read the docs
TI-2020-07010 Aliases CVE-2020-8745GHSA-wc8w-gx27-xp92

Insufficient control flow management in subsystem for Intel(R) CSME versions before…

Priority LOW 30Published · Updated

Key facts

Attack vector
Physical
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access.

Why it matters now

EPSS 0.00383 32nd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Intel(R) CSME, Intel(R) TXEIntel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30—No fix listedCNA
  • Intel(R) CSME, Intel(R) TXE Vendor— Affected Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 Fixed in — No fix listed CNA

CPE configurations NVD · 43

CPEVersionsRoleVendor
cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:*before 11.8.80; 11.12.0 to before 11.12.80; 11.22.0 to before 11.22.80; 12.0 to before 12.0.70; 14.0 to before 14.0.45; 14.5.0 to before 14.5.25VulnerableIntel
cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:*before 3.1.80; 4.0 to before 4.0.30VulnerableIntel
cpe:2.3:o:siemens:simatic_drive_controller_firmware:*:*:*:*:*:*:*:*before 05.00.01.00VulnerableSiemens
cpe:2.3:h:siemens:simatic_drive_controller:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_et200sp_1515sp_pc2_firmware:*:*:*:*:*:*:*:*before 0209.0105VulnerableSiemens
cpe:2.3:h:siemens:simatic_et200sp_1515sp_pc2:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*before 22.01.08VulnerableSiemens
cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:a:intel:converged_security_and_manageability_engine:*:*:*:*:*:*:*:* Versions before 11.8.80; 11.12.0 to before 11.12.80; 11.22.0 to before 11.22.80; 12.0 to before 12.0.70; 14.0 to before 14.0.45; 14.5.0 to before 14.5.25 Vulnerable ·Intel
  • cpe:2.3:a:intel:trusted_execution_technology:*:*:*:*:*:*:*:* Versions before 3.1.80; 4.0 to before 4.0.30 Vulnerable ·Intel
  • cpe:2.3:o:siemens:simatic_drive_controller_firmware:*:*:*:*:*:*:*:* Versions before 05.00.01.00 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_drive_controller:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_et200sp_1515sp_pc2_firmware:*:*:*:*:*:*:*:* Versions before 0209.0105 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_et200sp_1515sp_pc2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:* Versions before 22.01.08 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
Show 33 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*before 27.01.05VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*before 27.01.05VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*before 21.01.15VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc527g_firmware:*:*:*:*:*:*:*:*before 1.4.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc527g:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:*before r1.30.0VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*before 25.02.08VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*before 25.02.08VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc667e_firmware:*:*:*:*:*:*:*:*before 25.02.08VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc667e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*before 25.02.08VulnerableSiemens
cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*before 23.01.08VulnerableSiemens
cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_828d_hw_pu.4_firmware:*:*:*:*:*:*:*:*before 08.00.00.00VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_828d_hw_pu.4:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_mc_mcu_1720_firmware:*:*:*:*:*:*:*:*before 05.00.00.00VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_840d_sl_ht_10_firmware:-:*:*:*:*:*:*:*not specified by NVDVulnerableSiemens
cpe:2.3:h:siemens:sinumerik_840d_sl_ht_10:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_one_ncu_1740_firmware:*:*:*:*:*:*:*:*before 04.00.00.00VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_one_ncu_1740:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
cpe:2.3:o:siemens:sinumerik_one_ppu_1740_firmware:*:*:*:*:*:*:*:*before 06.00.00.00VulnerableSiemens
cpe:2.3:h:siemens:sinumerik_one_ppu_1740:-:*:*:*:*:*:*:*not specified by NVDRunning onSiemens
  • cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:* Versions before 27.01.05 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:* Versions before 27.01.05 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:* Versions before 21.01.15 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc527g_firmware:*:*:*:*:*:*:*:* Versions before 1.4.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc527g:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc547g_firmware:*:*:*:*:*:*:*:* Versions before r1.30.0 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:* Versions before 25.02.08 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:* Versions before 25.02.08 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc667e_firmware:*:*:*:*:*:*:*:* Versions before 25.02.08 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc667e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:* Versions before 25.02.08 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:* Versions before 23.01.08 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_828d_hw_pu.4_firmware:*:*:*:*:*:*:*:* Versions before 08.00.00.00 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_828d_hw_pu.4:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_mc_mcu_1720_firmware:*:*:*:*:*:*:*:* Versions before 05.00.00.00 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_mc_mcu_1720:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_840d_sl_ht_10_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_840d_sl_ht_10:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_one_ncu_1740_firmware:*:*:*:*:*:*:*:* Versions before 04.00.00.00 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_one_ncu_1740:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens
  • cpe:2.3:o:siemens:sinumerik_one_ppu_1740_firmware:*:*:*:*:*:*:*:* Versions before 06.00.00.00 Vulnerable ·Siemens
  • cpe:2.3:h:siemens:sinumerik_one_ppu_1740:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Siemens

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-8745
  2. 2026-10-03 Alias added: GHSA-wc8w-gx27-xp92

References

Sources