Read the docs
TI-2020-08107 Aliases CVE-2020-10050GHSA-666m-7m3w-f97c

Incorrect default permissions in Siemens SIMATIC RTLS Locating Manager

Priority LOW 34CWE-276Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts.

Why it matters now

EPSS 0.00286 21st percentileScored 2026-11-07
Fix Fixed SIMATIC RTLS Locating Manager (Siemens AG): V2.10.2

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSIMATIC RTLS Locating Managerbefore V2.10.2V2.10.2Patch availableCNA
  • SIMATIC RTLS Locating Manager VendorSiemens Affected before V2.10.2 Fixed in V2.10.2 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*before 2.10.2VulnerableSiemens
  • cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:* Versions before 2.10.2 Vulnerable ·Siemens

Remediation

  • Fix · CNA SIMATIC RTLS Locating Manager (Siemens AG) Fixed in V2.10.2

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-10050
  2. 2026-10-03 Alias added: GHSA-666m-7m3w-f97c

References

  • TI-2025-27214 Improper input validation in Siemens SIMATIC RTLS Locating Manager CVSS 4.0CRITICAL 9.4
  • TI-2020-08108 A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions <… CVSS 3.1HIGH 7.8
  • TI-2020-08106 Incorrect default permissions in Siemens SIMATIC RTLS Locating Manager CVSS 3.1HIGH 7.3
  • TI-2025-21405 Reachable assertion in Siemens SIMATIC RTLS Locating Manager CVSS 4.0MEDIUM 6.9
  • TI-2020-08111 Improper input validation in Siemens SIMATIC RTLS Locating Manager CVSS 3.1MEDIUM 5.5
  • TI-2020-08110 Cleartext storage of sensitive information in Siemens SIMATIC RTLS Locating Manager CVSS 3.1MEDIUM 5.5
See all 8 →